Department of Otolaryngology, University of Miami, Miami, FL, 33136, USA.
Department of Biomedical Engineering, University of Miami, Miami, FL, 33136, USA.
Hear Res. 2023 Feb;428:108680. doi: 10.1016/j.heares.2022.108680. Epub 2022 Dec 20.
Mild therapeutic hypothermia (MTH) has been demonstrated to prevent residual hearing loss from surgical trauma associated with cochlear implant (CI) insertion. Here, we aimed to characterize the mechanisms of MTH-induced hearing preservation in CI in a well-established preclinical rodent model.
Rats were divided into four experimental conditions: MTH-treated and implanted cochleae, cochleae implanted under normothermic conditions, MTH only cochleae and un-operated cochleae (controls). Auditory brainstem responses (ABRs) were recorded at different time points (up to 84 days) to confirm long-term protection and safety of MTH locally applied to the cochlea for 20 min before and after implantation. Transcriptome sequencing profiling was performed on cochleae harvested 24 h post CI and MTH treatment to investigate the potential beneficial effects and underlying active gene expression pathways targeted by the temperature management.
MTH treatment preserved residual hearing up to 3 months following CI when compared to the normothermic CI group. In addition, MTH applied locally to the cochleae using our surgical approach was safe and did not affect hearing in the long-term. Results of RNA sequencing analysis highlight positive modulation of signaling pathways and gene expression associated with an activation of cellular inflammatory and immune responses against the mechanical damage caused by electrode insertion.
These data suggest that multiple and possibly independent molecular pathways play a role in the protection of residual hearing provided by MTH against the trauma of cochlear implantation.
轻度治疗性低温(MTH)已被证明可预防与人工耳蜗(CI)植入相关的手术创伤引起的残余听力损失。在这里,我们旨在通过成熟的临床前啮齿动物模型来确定 MTH 诱导 CI 中听力保护的机制。
将大鼠分为四个实验条件:MTH 处理和植入耳蜗、在正常体温条件下植入耳蜗、仅 MTH 处理耳蜗和未手术耳蜗(对照)。在不同时间点(最长 84 天)记录听觉脑干反应(ABR),以确认 MTH 局部应用于耳蜗 20 分钟前后对植入后的长期保护和安全性。在 CI 和 MTH 治疗后 24 小时采集耳蜗进行转录组测序分析,以研究潜在的有益效果和靶向温度管理的潜在活性基因表达途径。
与正常体温 CI 组相比,MTH 处理可在 CI 后长达 3 个月内保留残余听力。此外,我们的手术方法局部应用于耳蜗的 MTH 是安全的,不会对长期听力产生影响。RNA 测序分析的结果突出了与对电极插入引起的机械损伤的细胞炎症和免疫反应激活相关的信号通路和基因表达的正向调节。
这些数据表明,多种可能独立的分子途径在 MTH 对耳蜗植入创伤引起的残余听力保护中发挥作用。