Suppr超能文献

头颅侧位X线摄影对成功实施盲探鼻插管的有用性:一项前瞻性研究。

Usefulness of lateral cephalometric radiography for successful blind nasal intubation: a prospective study.

作者信息

Ito Kana, Kamura Ayaka, Koshika Kyotaro, Handa Toshiyuki, Matsuura Nobuyuki, Ichinohe Tatsuya

机构信息

Department of Dental Anesthesiology, Tokyo Dental College, Tokyo, Japan.

Department of Oral Medicine and Hospital Dentistry, Ichikawa General Hospital, Tokyo Dental College, Tokyo, Japan.

出版信息

J Dent Anesth Pain Med. 2022 Dec;22(6):427-435. doi: 10.17245/jdapm.2022.22.6.427. Epub 2022 Nov 24.

Abstract

BACKGROUND

This study aimed to investigate the relationship between pharyngeal morphology and the success or failure of blind nasotracheal intubation using standard lateral cephalometric radiography and to analyze the measurement items affecting the difficulty of blind nasotracheal intubation.

METHODS

Assuming a line perpendicular to the Frankfort horizontal (FH) plane, the reference point (O) was selected 1 cm above the posterior-most end of the hard palate. A line passing through the reference point and parallel to the FH plane is defined as the X-axis, and a line passing through the reference point and perpendicular to the X-axis is defined as the Y-axis. The shortest length between the tip of the uvula and posterior pharyngeal wall (AW), shortest length between the base of the tongue and posterior pharyngeal wall (BW), and width of the glottis (CW) were measured. The midpoints of the lines representing each width are defined as points A, B, and C, and the X and Y coordinates of each point are obtained (AX, BX, CX, AY, BY, and CY). For each measurement, a t-test was performed to compare the tracheal intubation success and failure groups. A binomial logistic regression analysis was performed using clinically relevant items.

RESULTS

The items significantly affecting the success rate of blind nasotracheal intubation included the difference in X coordinates at points A and C (Odds ratio, 0.714; P-value, 0.024) and the ∠ABC (Odds ratio, 1.178; P-value, 0.016).

CONCLUSION

Using binomial logistic regression analysis, we observed statistically significant differences in AX-CX and ∠ABC between the success group and the failure group.

摘要

背景

本研究旨在利用标准头颅侧位X线片探讨咽部形态与盲探经鼻气管插管成败之间的关系,并分析影响盲探经鼻气管插管难度的测量项目。

方法

假设一条垂直于法兰克福水平面(FH平面)的线,参考点(O)选在硬腭最后端上方1cm处。经过参考点且平行于FH平面的线定义为X轴,经过参考点且垂直于X轴的线定义为Y轴。测量悬雍垂尖端与咽后壁之间的最短长度(AW)、舌根与咽后壁之间的最短长度(BW)和声门宽度(CW)。代表各宽度的线的中点定义为A、B、C点,并获取各点的X和Y坐标(AX、BX、CX、AY、BY和CY)。对于每项测量,进行t检验以比较气管插管成功组和失败组。使用临床相关项目进行二项式逻辑回归分析。

结果

显著影响盲探经鼻气管插管成功率的项目包括A点和C点X坐标的差异(优势比,0.714;P值,0.024)和∠ABC(优势比,1.178;P值,0.016)。

结论

通过二项式逻辑回归分析,我们观察到成功组和失败组在AX-CX和∠ABC方面存在统计学显著差异。