Birch D G, Sandberg M A
Retina Foundation of the Southwest, Presbyterian Medical Center, Dallas, TX 75231.
Vision Res. 1987;27(7):1105-12. doi: 10.1016/0042-6989(87)90025-3.
Computer-averaged full-field rod and cone electroretinograms (ERGs) were evaluated in 63 patients with retinitis pigmentosa and 116 normal subjects. Cone b-wave implicit times to 30 Hz white flicker and to 1.0 Hz white flashes on a white background were both inversely proportional to the log amplitude of the dark-adapted rod b-wave, even when controlling for the log amplitude of the dark-adapted cone b-wave. Cone ERGs were also obtained from a subset of 12 patients with retinitis pigmentosa in the presence of photopically-matched red and blue backgrounds that allowed direct assessment of the effect of rod function on cone b-wave implicit time in the patients. The effectiveness of the blue background in reducing cone b-wave implicit time relative to that obtained with the red background varied with the amplitude of the rod ERG. The results of both experiments suggest that delays in cone b-wave implicit time obtained with 30 Hz white flicker or with background adaptation in patients with retinitis pigmentosa are due, at least in part, to rod disease.
对63例视网膜色素变性患者和116名正常受试者的计算机平均全视野视杆和视锥细胞视网膜电图(ERG)进行了评估。即使在控制暗适应视锥细胞b波对数振幅的情况下,30Hz白色闪烁和白色背景上1.0Hz白色闪光刺激下的视锥细胞b波隐含时间均与暗适应视杆细胞b波的对数振幅成反比。还从12例视网膜色素变性患者的亚组中获取了视锥细胞ERG,此时存在明视觉匹配的红色和蓝色背景,这使得能够直接评估视杆细胞功能对患者视锥细胞b波隐含时间的影响。相对于红色背景,蓝色背景在减少视锥细胞b波隐含时间方面的有效性随视杆细胞ERG的振幅而变化。两个实验的结果均表明,视网膜色素变性患者在30Hz白色闪烁或背景适应时获得的视锥细胞b波隐含时间延迟至少部分归因于视杆细胞疾病。