BMC Ophthalmol. 2023 Jan 9;23(1):12. doi: 10.1186/s12886-023-02769-9.
To investigate the effects of rigid gas permeable contact lens (RGP-CL) wear on contrast visual acuity in patients after penetrating keratoplasty.
Nineteen patients (19 eyes), aged 30.45 ± 5.83 years, who had received penetrating keratoplasty and were successfully fitted with RGP-CLs at our hospital from July 2017 to June 2018 were included. Contrast visual acuities at 100%, 25%, and 10% with spectacles and RGP-CLs were analyzed using the Chi-square test. The wavefront aberrations at the anterior surface of the cornea before and 1 month after RGP-CL wear were compared using the matched sample t-test.
The mean best spectacle-corrected visual acuities were 0.390 ± 0.135 logMAR, 0.706 ± 0.182 logMAR, and 0.952 ± 0.223 logMAR at the 100%, 25%, and 10% contrast levels, respectively, which were significantly lower than the RGP-CL-corrected visions at the three levels (0.255 ± 0.133 logMAR, 0.488 ± 0.168 logMAR, and 0.737 ± 0.159 logMAR; all P < 0.001). The vision losses with RGP-CLs were 0.231 ± 0.099 logMAR and 0.466 ± 0.094 logMAR at the 25% and 10% contrast levels, respectively. The Zernike spherical aberration Z was reduced from 3.734 ± 1.061 μm to 2.622 ± 0.725 μm after wearing the RGP-CLs (P ≤ 0.001). The astigmatism parameters of Z and Z were also reduced from 3.761 ± 2.309 μm and 3.316 ± 2.147 μm to 2.637 ± 1.722 μm and 2.016 ± 1.184 μm, respectively (P < 0.05).
For post-keratoplasty patients, RGP-CLs can help to improve visual performance, especially low contrast visual acuity. The improvement may be related to the reduction of corneal aberrations, mainly the spherical and astigmatism aberrations.
研究硬性透气性角膜接触镜(RGP-CL)对穿透性角膜移植术后患者对比敏感度视力的影响。
纳入 2017 年 7 月至 2018 年 6 月在我院成功接受穿透性角膜移植术并佩戴 RGP-CL 的 19 例(19 眼)患者,年龄 30.45±5.83 岁。使用卡方检验分析戴眼镜和 RGP-CL 时 100%、25%和 10%对比度的对比敏感度视力。采用配对样本 t 检验比较佩戴 RGP-CL 前后角膜前表面的波前像差。
最佳矫正视力分别为戴眼镜时的 0.390±0.135 logMAR、0.706±0.182 logMAR 和 0.952±0.223 logMAR,低于佩戴 RGP-CL 时的视力(分别为 0.255±0.133 logMAR、0.488±0.168 logMAR 和 0.737±0.159 logMAR;均 P<0.001)。25%和 10%对比度时,RGP-CL 引起的视力损失分别为 0.231±0.099 logMAR 和 0.466±0.094 logMAR。佩戴 RGP-CL 后,Zernike 球差 Z 从 3.734±1.061 μm 降低至 2.622±0.725 μm(P≤0.001)。Z 和 Z 的散光参数也从 3.761±2.309 μm 和 3.316±2.147 μm 降低至 2.637±1.722 μm 和 2.016±1.184 μm(P<0.05)。
对于角膜移植术后患者,RGP-CL 可以帮助改善视力,特别是低对比度视力。这种改善可能与角膜像差的减少有关,主要是球差和散光像差。