In this paper, the connection performance of extrusion sleeves and the strain rate effect on 500 MPa-grade hot-rolled ribbed bar(HRB500E) connected with extrusion sleeves under a range of testing strain rates from 1.079/sto1.395/s, similar to what would be caused by an impact, were explored. The test results showed that, under strain rates likely caused by aircraft impact, the specimens mostly failed due to breaking outside the joint length. Furthermore, there was no relative slip between the rebar and the extrusion sleeve, indicating that the connection was stable and reliable in the used experimental parameter field. The percentage total elongation at maximum force () of HRB500E spliced by the extrusion sleeve showed an exponential decline with the increase in the strain rate, indicating a clear strain-rate sensitivity. The average deviation between the dynamic increase factors () calculated using the modified Cowper-Symonds formulas and the experimental values was within 5.4%, which can better reflect the strain rate effect on the strength of the spliced connection. The of sleeve-spliced rebars was higher than that of unspliced rebars, and the ratio of the of sleeve-spliced rebars to the of unspliced rebars increased with the strain rate. The experimental results can provide a basis for an optimized design of the aircraft impact-resistant extrusion sleeve rebar connections.
本文研究了挤压套筒的连接性能,以及在1.079/s至1.395/s的一系列测试应变率下(类似于冲击可能产生的应变率),与挤压套筒连接的500MPa级热轧带肋钢筋(HRB500E)的应变率效应。试验结果表明,在飞机冲击可能产生的应变率下,试件大多因在接头长度以外断裂而破坏。此外,钢筋与挤压套筒之间没有相对滑移,表明在所使用的试验参数范围内连接稳定可靠。挤压套筒拼接的HRB500E在最大力下的总伸长率百分比()随应变率的增加呈指数下降,表明具有明显的应变率敏感性。使用修正的Cowper-Symonds公式计算的动力增大系数()与试验值之间的平均偏差在5.4%以内,能较好地反映应变率对拼接连接强度的影响。套筒拼接钢筋的比未拼接钢筋的高,且套筒拼接钢筋的与未拼接钢筋的之比随应变率增加。试验结果可为飞机抗冲击挤压套筒钢筋连接的优化设计提供依据。