Suppr超能文献

不同牙尖倾斜度对上颌第一磨牙短种植体修复效果的三年观察:一项随机对照试验

Three-year observations on the effect of different cusp inclinations on the restoration of short maxillary first molar implants: A randomized controlled trial.

作者信息

Cheng Yuye, Xiao Cong, Zhu Yu, Chen Qiuyan, Zhang Longbo, Zhang Yanshu, Gao Meiqin, Li Xinpei, Zhou Yan, Song Guiqiang, Zhang Tiecheng, Pei Runsheng

机构信息

Department of Prosthodontics, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China.

Department of Orthodontics, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China.

出版信息

Front Physiol. 2023 Jan 4;13:992800. doi: 10.3389/fphys.2022.992800. eCollection 2022.

Abstract

To investigate the effect of different cusp inclination on short implant prosthesis of maxillary first molar after 3 years of weight-bearing in biology and mechanics. The clinical patients were randomly selected from the database and divided into four groups A, B, C, and D according to the cusp inclination of the maxillary first molar short implant restoration (4.8 mm × 8 mm, Dentium). 20 cases in each group. The cusp inclination was 10 degrees-15 degrees, 15 degrees-20 degrees, 20 degrees-25 degrees, 25 degrees-30 degrees. After 3 years of weight-bearing, cone beam computed tomography (CBCT) and Florida probe were used to measure and observe the height of alveolar bone (H), periodontal probing depth (PD) and modified sulcus bleeding index (MBI). Visual analogue scale (VAS) was used to evaluate the overall satisfaction of patients, and the mechanical complications of each group within 3 years of implant weight-bearing were counted. The H and PD of group D were 1.09 ± 0.23 and 2.19 ± 0.11 respectively, which were significantly higher than those of group A, B and C ( < 0.05). There was no significant difference in MBI between groups A-D ( > 0.05). The VAS scores of group B and group C were 88.36 ± 5.12 and 88.70 ± 4.52 respectively, which were higher than those of group A and group D ( < 0.05). The incidence of food impaction, porcelain collapse and abutment loosening in group D were 40.0%, 25.0% and 15.0% respectively, which were higher than those in group B and C ( < 0.05). The risk of biological and mechanical complications increases after long-term weight-bearing of maxillary first molar short implant prostheses with high cusp inclination. The cusp inclination of short implant prostheses should be designed as low as 25 degrees.

摘要

为研究不同牙尖斜度对上颌第一磨牙短种植体义齿负重3年后生物学和力学方面的影响。从数据库中随机选取临床患者,根据上颌第一磨牙短种植体修复体(4.8mm×8mm,登腾)的牙尖斜度分为A、B、C、D四组。每组20例。牙尖斜度分别为10度 - 15度、15度 - 20度、20度 - 25度、25度 - 30度。负重3年后,采用锥形束计算机断层扫描(CBCT)和佛罗里达探针测量并观察牙槽骨高度(H)、牙周探诊深度(PD)和改良龈沟出血指数(MBI)。采用视觉模拟评分法(VAS)评估患者的总体满意度,并统计种植体负重3年内每组的机械并发症情况。D组的H和PD分别为1.09±0.23和2.19±0.11,显著高于A、B、C组(P<0.05)。A - D组间MBI无显著差异(P>0.05)。B组和C组的VAS评分分别为88.36±5.12和88.70±4.52,高于A组和D组(P<0.05)。D组食物嵌塞、瓷崩和基台松动的发生率分别为40.0%、25.0%和15.0%,高于B组和C组(P<0.05)。高牙尖斜度的上颌第一磨牙短种植体义齿长期负重后生物学和机械并发症风险增加。短种植体义齿的牙尖斜度应设计得低至25度。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/744a/9845769/1ec9e2944ceb/fphys-13-992800-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验