Niccum N, Speaks C, Katsuki-Nakamura J, Van Tasell D
University of Minnesota, Minneapolis.
J Speech Hear Disord. 1987 Nov;52(4):313-8. doi: 10.1044/jshd.5204.313.
This experiment assessed conditions under which simulated conductive hearing loss would affect performance on a digit dichotic test. Losses were simulated by insertion of EAR plugs, and each subject served as his/her own control. Performance for left ear plugged and right ear plugged conditions was compared with performance in a normal hearing condition (neither ear plugged). Conductive losses did not affect dichotic performance at test intensities 12 dB above the "knees" of monotic performance-intensity functions for the plugged ears (95% correct points) but did affect dichotic performance for some listeners at intensities that were within 8 dB of the monotic knees.
本实验评估了模拟传导性听力损失在何种条件下会影响数字双耳分听测试的表现。通过插入耳塞来模拟听力损失,且每位受试者均作为自己的对照。将左耳堵塞和右耳堵塞条件下的表现与正常听力条件(双耳均未堵塞)下的表现进行比较。在测试强度高于堵塞耳单耳表现-强度函数“拐点”12分贝时(95%正确得分点),传导性听力损失并未影响双耳分听表现,但在强度处于单耳拐点8分贝范围内时,一些受试者的双耳分听表现受到了影响。