A gas chromatographic method for the determination of the mixture of organic solvents in air has been developed. The optimum conditions of the separation of the mixture were obtained in the column packed with 10% UCON HB 2000 coated on Chromosorb W AW DMCS 80-100 mesh. The components of the mixture are collected on activated charcoal and desorbed with CS2. A quantitative analysis is made using methyl isobutyl ketone as an internal standard. The lowest detectable limit under proposed air sampling and analysis conditions is 0.1 TLV (threshold limit value) for each component of the mixture.