Nino-Barrera Javier Laureano, Aldana-Ojeda Laura, Gamboa-Martinez Luis Fernando, Acosta-Humanez Manuel, Silva-Castellanos Christian, Cortes-Rodriguez Carlos Julio
Universidad Nacional de Colombia, Department of Basic Sciences and Oral Medicine, School of Dentistry, Bogota, Colombia.
Universidad el Bosque, School of Dentistry, Bogota, Colombia.
Iran Endod J. 2021;16(1):49-55. doi: 10.22037/iej.v16i1.24048.
The objective of this study was to compare the mechanical and structural properties of the nickel-titanium (Ni-Ti) alloy already used in endodontics with titanium-molybdenum (Ti-Mo) and titanium-niobium (Ti-Nb) alloys to determine if these can be suggested in the manufacture of endodontic files.
Orthodontic wires made of the different alloys were used. The previously mentioned alloys were characterized by energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and torsion tests. Cyclic fatigue tests were performed on a simulated canal with a curvature of 86° to 375 rpm. The fractured surfaces of the wires were observed by means of scanning electron microscopy (SEM). A Kruskal-Wallis test and U Mann Whitney test were used to determine significant differences in cyclic fatigue between groups.
In the mechanical tests, similar values of torsion were found for the three alloys. In XRD, the Ti-Nb showed less structural changes. In the cyclic fatigue test, Ti-Nb was found to be significantly more resistant with respect to Ni-Ti and Ti-Mo.
Based on our study, Ti-Nb is suggested as a possible alloy for the manufacture of rotary files due to its impressive properties.
本研究的目的是比较已用于牙髓病学的镍钛(Ni-Ti)合金与钛钼(Ti-Mo)和钛铌(Ti-Nb)合金的机械性能和结构性能,以确定这些合金是否可用于制造牙髓锉。
使用由不同合金制成的正畸丝。通过能量色散X射线光谱法(EDX)、X射线衍射(XRD)和扭转试验对上述合金进行表征。在曲率为86°的模拟根管上以375转/分钟的速度进行循环疲劳试验。通过扫描电子显微镜(SEM)观察丝的断裂表面。使用Kruskal-Wallis检验和U Mann Whitney检验来确定各组之间循环疲劳的显著差异。
在机械试验中,三种合金的扭转值相似。在XRD中,Ti-Nb的结构变化较小。在循环疲劳试验中,发现Ti-Nb相对于Ni-Ti和Ti-Mo具有显著更高的抗性。
基于我们的研究,由于其令人印象深刻的性能,建议将Ti-Nb作为制造旋转锉的一种可能合金。