Abstract

OBJECTIVE

To report the diagnostic utility of the novel, high-ventilatory task assessment tool called the Milstein Breathing Pattern Assessment Index (M-BPAI) for evaluation of Breathing Pattern Disorder (BPD) in athletes with and without breathing difficulty, and to evaluate the prevalence of BPD in athletes referred for Exercise Induced Laryngeal Obstruction (EILO). BPD is an abnormal respiratory biomechanical pattern caused from functional or structural factors. The presence of BPD in athletes with EILO is unknown. The current clinical evaluations of dysfunctional breathing patterns are limiting for evaluation of BPD in patients with EILO, as these only evaluate the patients in low ventilatory output tasks of rest breathing.

STUDY DESIGN AND METHODS

In this prospective study, a total of 77 athletes referred to the clinic for suspected EILO and 58 athletes without any respiratory difficulty underwent M-BPAI assessment. Data collection from the experimental group also included the Dyspnea Index, and laryngeal video endoscopic provocation test.

RESULTS

The M-BPAI score was significantly larger in the patient group compared to the control group. An overall M-BPAI score of ≥8 corresponds to the AUC of 0.87 (95% CI: 0.81-0.93) with a sensitivity of 0.862 and specificity of 0.792. A total of 60 (78%) patients had an overall M-BPAI score of ≥8.

CONCLUSION

The M-BPAI has the potential to be a valuable clinical diagnostic marker for identifying BPD in patients with suspected EILO with further research and validation.

摘要

目的

报告一种名为米尔斯坦呼吸模式评估指数(M - BPAI)的新型高通气任务评估工具在评估有或无呼吸困难的运动员呼吸模式障碍(BPD)方面的诊断效用,并评估因运动性喉梗阻(EILO)转诊的运动员中BPD的患病率。BPD是由功能或结构因素引起的异常呼吸生物力学模式。EILO运动员中BPD的存在情况尚不清楚。目前对功能失调呼吸模式的临床评估在评估EILO患者的BPD方面存在局限性,因为这些评估仅在静息呼吸的低通气输出任务中对患者进行评估。

研究设计与方法

在这项前瞻性研究中,共有77名因疑似EILO转诊至诊所的运动员和58名无任何呼吸困难的运动员接受了M - BPAI评估。实验组的数据收集还包括呼吸困难指数和喉镜视频激发试验。

结果

与对照组相比,患者组的M - BPAI评分显著更高。总体M - BPAI评分≥8对应的曲线下面积(AUC)为0.87(95%可信区间:0.81 - 0.93),敏感性为0.862,特异性为0.792。共有60名(78%)患者的总体M - BPAI评分≥8。

结论

经过进一步研究和验证,M - BPAI有可能成为识别疑似EILO患者BPD的有价值的临床诊断标志物。