J Vis Exp. 2023 Jan 20(191). doi: 10.3791/64410.
A preload challenge (PC) is a clinical maneuver that, first, increases the cardiac filling (i.e., preload) and, second, calculates the change in cardiac output. Fundamentally, a PC is a bedside approach for testing the Frank-Starling-Sarnoff (i.e., "cardiac function") curve. Normally, this curve has a steep slope such that a small change in the cardiac preload generates a large change in the stroke volume (SV) or cardiac output. However, in various disease states, the slope of this relationship flattens such that increasing the volume into the heart leads to little rise in the SV. In this pathological scenario, additional cardiac preload (e.g., intravenous fluid) is unlikely to be physiologically effective and could lead to harm if organ congestion evolves. Therefore, inferring both the cardiac preload and output is clinically useful as it may guide intravenous (IV) fluid resuscitation. Accordingly, the goal of this protocol is to describe a method for contemporaneously tracking the surrogates of cardiac preload and output using a novel, wireless, wearable ultrasound during a well-validated preload challenge.
预负荷挑战(PC)是一种临床操作,首先增加心脏充盈(即前负荷),其次计算心输出量的变化。从根本上讲,PC 是一种床边检测法兰克-斯塔林-萨诺夫(即“心功能”)曲线的方法。通常,该曲线斜率较大,即心脏前负荷的微小变化会导致心搏量(SV)或心输出量的大幅变化。然而,在各种疾病状态下,这种关系的斜率趋于平坦,导致心脏充盈量增加时 SV 升高幅度较小。在这种病理情况下,额外的心脏前负荷(例如静脉输液)不太可能具有生理效应,如果发生器官充血,可能会导致危害。因此,推断心脏前负荷和输出具有临床意义,因为它可能指导静脉(IV)液体复苏。因此,本方案的目的是描述一种使用新型无线可穿戴超声在经过充分验证的预负荷挑战期间同时跟踪心脏前负荷和输出替代指标的方法。