新型具有先进光学设计的 toric 人工晶状体的旋转稳定性。

Rotational stability of a new toric intraocular lens with an advanced optical profile.

机构信息

From the Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria.

出版信息

J Cataract Refract Surg. 2023 Jun 1;49(6):584-588. doi: 10.1097/j.jcrs.0000000000001158.

Abstract

PURPOSE

To examine the rotational stability of a new toric intraocular lens (IOL), the TECNIS Eyhance Toric II, over a course of 3 months.

SETTING

Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria.

DESIGN

Prospective unmasked single-center study.

METHODS

50 eyes of 50 patients with cataract and regular corneal astigmatism ≥0.75 diopters (D) were included. The TECNIS Eyhance Toric II IOL was implanted in 1 eye of each study patient. Images of the alignment axis of the IOL were taken intraoperatively, as well as at 1 hour, 1 week, and 3 months postoperatively. For the measurement of toric IOL rotation, images were superimposed on the basis of ocular landmarks. Uncorrected and corrected distance (4 m) and intermediate (66 cm) visual acuities were assessed at the 3-month visit.

RESULTS

There was no significant difference in the rotational position between the intraoperative and 3 month timepoints, with a mean rotation of 1.34 ± 1.46 degrees, in 27 examined eyes. ( P = 0.313). No patients had to undergo repositioning of the toric IOL. A significant reduction of refractive cylinder occurred from preoperatively 1.8 ± 1.1 to 0.40 ± 0.42 D at the 3-month visit ( P = .001; n = 43). The corrected distance visual acuity improved significantly from 0.28 ± 0.16 logMAR preoperatively to -0.01 ± 0.13 logMAR at 3 months postoperatively ( P = .001; n = 43).

CONCLUSIONS

The TECNIS Eyhance Toric II showed a good visual performance with no significant rotation over a course of 3 months and, therefore, an excellent rotational stability. The intraocular lens showed a good safety profile with no adverse events.

摘要

目的

研究新型 toric 人工晶状体(IOL)——TECNIS Eyhance Toric II 在 3 个月内的旋转稳定性。

设置

维也纳眼科手术研究所,维也纳 Hanusch 医院,奥地利。

设计

前瞻性非盲单中心研究。

方法

纳入 50 例(50 只眼)白内障合并规则性角膜散光≥0.75 屈光度(D)的患者。每位研究患者的 1 只眼植入 TECNIS Eyhance Toric II IOL。术中、术后 1 小时、1 周和 3 个月时拍摄 IOL 光轴图像。为了测量 toric IOL 的旋转,通过眼球标志对图像进行叠加。在 3 个月时评估未矫正和矫正的远(4 m)、中(66 cm)距视力。

结果

在 27 只检查眼中,手术中与 3 个月时的旋转位置无显著差异,平均旋转 1.34±1.46 度( P = 0.313)。无患者需要重新定位 toric IOL。从术前的 1.8±1.1 D 到 3 个月时的 0.40±0.42 D,屈光性散光显著降低( P =.001;n = 43)。从术前的 0.28±0.16 logMAR 到术后 3 个月时的-0.01±0.13 logMAR,矫正远距视力显著提高( P =.001;n = 43)。

结论

TECNIS Eyhance Toric II 在 3 个月内表现出良好的视觉效果,旋转角度无显著变化,因此具有出色的旋转稳定性。该人工晶状体具有良好的安全性,无不良事件发生。