Current serological diagnosis of pertussis is usually performed by ELISA, which is typically performed in larger diagnostic or reference laboratories, requires trained staff, and due to sample batching may have longer turnaround times. A rapid point-of-care (POC) assay for pertussis serology would aid in both the diagnosis and surveillance of the disease. A quantitative lateral flow (LF)-based immunoassay with fluorescent Eu-nanoparticle reporters was developed for the detection of anti-pertussis toxin (PT) and adenylate cyclase toxin (ACT) antibodies from oral fluid samples (=100), from suspected pertussis cases with respiratory symptoms. LF assay results were compared to those obtained with anti-PT IgG oral fluid ELISA. For an ELISA cut-off value of 50 arbitrary units, the overall agreement between the assays was 91/100 (91 %), the sensitivity was 63/70 (90 %) and the specificity was 28/30 (93 %). No ACT-specific antibodies were detected from oral fluid samples; however, the signal readout positively correlated to those patients with high anti-PT IgG antibodies. The developed LF assay was a specific, sensitive and rapid test for serological diagnosis of pertussis with anti-PT antibodies and is a suitable POC test using oral fluid samples.
目前,针对百日咳的血清学诊断通常通过 ELISA 进行,而 ELISA 通常在较大型的诊断或参考实验室中进行,需要经过培训的工作人员,并且由于样本分批处理,可能需要较长的周转时间。一种用于百日咳血清学的快速即时检测(POC)检测方法将有助于疾病的诊断和监测。本研究开发了一种基于定量侧向流动(LF)的免疫测定法,该方法使用荧光 Eu 纳米颗粒报告分子,用于检测来自呼吸道症状疑似百日咳病例的口腔液样本中的抗百日咳毒素(PT)和腺苷酸环化酶毒素(ACT)抗体。将 LF 检测结果与通过抗-PT IgG 口腔液 ELISA 获得的结果进行比较。对于 ELISA 的 50 个任意单位的截断值,两种检测方法的总符合率为 91/100(91%),灵敏度为 63/70(90%),特异性为 28/30(93%)。从口腔液样本中未检测到任何 ACT 特异性抗体;然而,信号读出值与那些具有高抗-PT IgG 抗体的患者呈正相关。该研究开发的 LF 检测法是一种针对抗-PT 抗体的特异性、敏感性和快速的百日咳血清学诊断方法,并且是一种使用口腔液样本的适合 POC 的检测方法。