Different views about the value of a colour monitor for the evaluation of computer tomograms have prompted us to carry out this ROC (Receiver Operation Characteristic) examination. The latter was based on patient computer tomograms in which lesions of the liver were simulated by image manipulation. 5 radiologists analysed the image material (a) on a black-and-white monitor, (b) on a colour monitor, and (c) simultaneously on a black-and-white and a colour monitor. The study shows that the use of a colour monitor gives no essentially different result than evaluation with a black-and-white monitor. The slightly better result of 2% more true positive findings with simultaneous representation of black-and-white and colour image relative to the sole use of black-and-white display is within error limits. The colour representation gives no advantage for the evaluation of usual computer tomograms because the window technique enables a contrast representation in black-and-white too.
对于彩色显示器在计算机断层扫描评估中的价值存在不同观点,这促使我们进行了这项ROC(受试者操作特征)检查。该检查基于患者的计算机断层扫描,其中通过图像处理模拟肝脏病变。5位放射科医生对图像资料进行了分析:(a)在黑白显示器上,(b)在彩色显示器上,以及(c)同时在黑白和彩色显示器上。研究表明,使用彩色显示器与使用黑白显示器进行评估相比,结果并无本质差异。相对于仅使用黑白显示器,黑白和彩色图像同时显示时真阳性发现略多2%的稍好结果在误差范围内。对于常规计算机断层扫描的评估,彩色显示并无优势,因为窗口技术也能实现黑白对比度显示。