Suppr超能文献

Delta 陶瓷-陶瓷关节假体翻修全髋关节置换术的中期结果。

Mid-term Results of Revision Total Hip Arthroplasty Using Delta Ceramic-on-Ceramic Bearing.

机构信息

Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.

Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea.

出版信息

Clin Orthop Surg. 2023 Feb;15(1):20-26. doi: 10.4055/cios21192. Epub 2022 Jul 21.

Abstract

BACKGROUND

Delta ceramic-on-ceramic (CoC) articulation affords excellent outcomes in primary total hip arthroplasty (THA). However, the safety and reliability of this bearing in revision THA need more evidence. This study aimed to report complications, radiological changes, clinical results, and survivorship of revision THA using Delta CoC articulation at minimum 5-year follow-up.

METHODS

We reviewed 118 revision THAs (113 patients: 68 men and 45 women) performed with use of Delta CoC bearing. Their mean age was 58.7 years (range, 30-90 years) and their mean body mass index was 24.6 kg/m (range, 15.2-32.5 kg/m). These patients were followed up for 5-12 years (mean, 7.2 years). We evaluated squeak, grinding sensation, ceramic fracture, dislocation, periprosthetic joint infection (PJI), periprosthetic fracture, prosthetic loosening, ceramic wear, osteolysis, modified Harris hip score (mHHS), and survivorship with any reoperation after the revision as the endpoint.

RESULTS

Two patients (1.7%) had grinding sensation, but no patient had ceramic fracture. Reoperations were necessary in 9 hips (7.6%) due to PJIs in 2, stem loosening in 2, cup loosening in 2, recurrent dislocation in 2, and periprosthetic fracture in 1. No hip had measurable wear or osteolysis. The average mHHS improved from 53.3 points before the revision to 82.3 points at the final follow-up. Survivorship was 91.6% (95% confidence interval, 86.3%-96.9%) at 12 years.

CONCLUSIONS

The Delta ceramic bearing appeared a reliable option for revision THA, showing encouraging mid-term results with acceptable survivorship and a low complication rate.

摘要

背景

Delta 陶瓷-陶瓷(CoC)关节在初次全髋关节置换术(THA)中具有出色的效果。然而,这种关节在翻修 THA 中的安全性和可靠性需要更多证据。本研究旨在报告最低 5 年随访时采用 Delta CoC 关节的翻修 THA 的并发症、影像学变化、临床结果和生存率。

方法

我们回顾了 118 例采用 Delta CoC 关节行翻修 THA 的病例(113 例患者:68 名男性和 45 名女性)。患者的平均年龄为 58.7 岁(范围 30-90 岁),平均体重指数为 24.6 kg/m(范围 15.2-32.5 kg/m)。这些患者的随访时间为 5-12 年(平均 7.2 年)。我们评估了异响、研磨感、陶瓷断裂、脱位、假体周围关节感染(PJI)、假体周围骨折、假体松动、陶瓷磨损、骨溶解、改良 Harris 髋关节评分(mHHS)以及以翻修后的任何再手术作为终点的生存率。

结果

有 2 例(1.7%)患者出现研磨感,但无陶瓷断裂。9 髋(7.6%)因 2 例 PJI、2 例柄松动、2 例杯松动、2 例复发性脱位和 1 例假体周围骨折需要翻修。没有髋关节出现可测量的磨损或骨溶解。平均 mHHS 从翻修前的 53.3 分提高到最终随访时的 82.3 分。12 年时的生存率为 91.6%(95%置信区间,86.3%-96.9%)。

结论

Delta 陶瓷关节似乎是翻修 THA 的可靠选择,中期结果令人鼓舞,具有可接受的生存率和较低的并发症发生率。