Suppr超能文献

即时诊断生物传感器监测唾液中抗 SARS-CoV-2 中和 IgG/sIgA 抗体和抗氧化活性。

Point-of-Care Diagnostic Biosensors to Monitor Anti-SARS-CoV-2 Neutralizing IgG/sIgA Antibodies and Antioxidant Activity in Saliva.

机构信息

Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan.

SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki 567-0047, Osaka, Japan.

出版信息

Biosensors (Basel). 2023 Jan 20;13(2):167. doi: 10.3390/bios13020167.

Abstract

Monitoring biomarkers is a great way to assess daily physical condition, and using saliva instead of blood samples is more advantageous as the process is simple and allows individuals to test themselves. In the present study, we analyzed the titers of neutralizing antibodies, IgG and secretory IgA (sIgA), in response to the SARS-CoV-2 vaccine, in saliva. A total of 19 saliva and serum samples were collected over a 10-month period 3 weeks after the first vaccine, 8 months after the second vaccine, and 1 month after the third vaccine. The ranges of antibody concentrations post-vaccination were: serum IgG: 81-15,000 U/mL, salivary IgG: 3.4-330 U/mL, and salivary IgA: 58-870 ng/mL. A sharp increase in salivary IgG levels was observed after the second vaccination. sIgA levels also showed an increasing trend. A correlation with trends in serum IgG levels was observed, indicating the possibility of using saliva to routinely assess vaccine efficacy. The electrochemical immunosensor assay developed in this study based on the gold-linked electrochemical immunoassay, and the antioxidant activity measurement based on luminol electrochemiluminescence (ECL), can be performed using portable devices, which would prove useful for individual-based diagnosis using saliva samples.

摘要

监测生物标志物是评估日常身体状况的一种很好的方法,而使用唾液代替血液样本更具优势,因为该过程简单,并且允许个体进行自我检测。在本研究中,我们分析了唾液中针对 SARS-CoV-2 疫苗的中和抗体、IgG 和分泌型 IgA(sIgA)的滴度。总共收集了 19 份唾液和血清样本,在第一剂疫苗接种后 3 周、第二剂疫苗接种后 8 个月和第三剂疫苗接种后 1 个月进行了 10 个月的监测。接种后抗体浓度范围如下:血清 IgG:81-15000 U/mL,唾液 IgG:3.4-330 U/mL,唾液 IgA:58-870 ng/mL。第二次接种后,唾液 IgG 水平急剧上升。sIgA 水平也呈现出上升趋势。与血清 IgG 水平的趋势相关,表明使用唾液常规评估疫苗效力的可能性。本研究基于金连接电化学免疫分析和基于鲁米诺电化学发光(ECL)的抗氧化活性测量开发的电化学免疫传感器分析,可以使用便携式设备进行,这对于使用唾液样本进行个体诊断将非常有用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3932/9953869/85d8972e1026/biosensors-13-00167-sch001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验