Suppr超能文献

放射造影剂的X射线衰减特性。

X-ray attenuation properties of radiographic contrast media.

作者信息

Lumbroso P, Dick C E

机构信息

National Bureau of Standards, Gaithersburg, Maryland 20899.

出版信息

Med Phys. 1987 Sep-Oct;14(5):752-8. doi: 10.1118/1.595999.

Abstract

A systematic study has been carried out to assess the x-ray attenuation properties of various elements when used as radiographic contrast enhancing media. This study examines the effects of solutions of molecules with effective atomic numbers from 40 to 92 on the signal-contrast ratio of radiographic images formed with various input x-ray spectra on suitable phantoms. A variety of x-ray spectra were used including monoenergetic spectra, constant potential x-ray tube spectra, and computed tomography spectra. In addition, a computer model was used to predict the effects studied. In general, the computer model is able to accurately predict the resulting signal-contrast ratio for a given combination of contrast media, input x-ray spectra, and phantom composition. From these data and calculations, it may be possible to design new contrast media which are tailored to specific diagnostic imaging tasks.

摘要

已经开展了一项系统性研究,以评估各种元素用作射线造影增强介质时的X射线衰减特性。本研究考察了有效原子序数从40到92的分子溶液对在合适的体模上使用各种输入X射线光谱形成的射线图像的信号对比度的影响。使用了多种X射线光谱,包括单能光谱、恒压X射线管光谱和计算机断层扫描光谱。此外,还使用了一个计算机模型来预测所研究的效应。总体而言,对于给定的造影剂、输入X射线光谱和体模组成的组合,该计算机模型能够准确预测所得的信号对比度。根据这些数据和计算,有可能设计出针对特定诊断成像任务的新型造影剂。