Commercial Smart Watches and Heart Rate Monitors: A Concurrent Validity Analysis.

机构信息

Wu Tsai Human Performance Alliance, Division of Cardiovascular Medicine, Stanford School of Medicine, Stanford University, Stanford, California.

Department of Kinesiology, The University of Texas at El Paso, El Paso, Texas.

出版信息

J Strength Cond Res. 2023 Sep 1;37(9):1802-1808. doi: 10.1519/JSC.0000000000004482. Epub 2023 Mar 2.

Abstract

Montalvo, S, Martinez, A, Arias, S, Lozano, A, Gonzalez, MP, Dietze-Hermosa, MS, Boyea, BL, and Dorgo, S. Smartwatches and commercial heart rate monitors: a concurrent validity analysis. J Strength Cond Res 37(9): 1802-1808, 2023-The purpose of this study was to explore the concurrent validity of 2 commercial smartwatches (Apple Watch Series 6 and 7) against a clinical criterion device (12-lead electrocardiogram [ECG]) and a field criterion device (Polar H-10) during exercise. Twenty-four male collegiate football players and 20 recreationally active young adults (10 men and 10 women) were recruited and participated in a treadmill-based exercise session. The testing protocol included 3 minutes of standing still (resting), then walking at low intensity, jogging at a moderate intensity, running at a high intensity, and postexercise recovery. The intraclass correlation (ICC 2,k ), and Bland-Altman plot analyses showed a good validity of the Apple Watch Series 6 and Series 7 with increased error (bias) as jogging and running speed increased in the football and recreational athletes. The Apple Watch Series 6 and 7 are highly valid smartwatches at rest and different exercise intensities, with validity decreasing with increased running speed. Strength and conditioning professionals and athletes can confidently use the Apple Watch Series 6 and 7 when tracking heart rate; however, caution must be taken when running at moderate or higher speeds. The Polar H-10 can surrogate a clinical ECG for practical applications.

摘要

蒙塔尔沃、S、马丁内斯、A、阿里亚斯、S、洛萨诺、A、冈萨雷斯、MP、迪策-赫尔莫萨、MS、博耶亚、BL 和多尔戈、S. 智能手表和商用心率监测器:并行有效性分析。J 力量与体能研究 37(9):1802-1808,2023 本研究旨在探索 2 款商用智能手表(Apple Watch Series 6 和 7)与临床标准设备(12 导联心电图[ECG])和现场标准设备(Polar H-10)在运动过程中的并行有效性。招募了 24 名男性大学生足球运动员和 20 名休闲活跃的年轻人(10 名男性和 10 名女性),并让他们参加了一项基于跑步机的运动测试。测试方案包括 3 分钟的静止(休息),然后以低强度行走,以中强度慢跑,以高强度跑步,以及运动后的恢复。组内相关系数(ICC 2,k)和 Bland-Altman 图分析表明,Apple Watch Series 6 和 7 的有效性良好,随着足球和休闲运动员的慢跑和跑步速度的增加,误差(偏差)增加。Apple Watch Series 6 和 7 在休息和不同运动强度时是高度有效的智能手表,随着跑步速度的增加,有效性降低。力量和体能专业人员和运动员在跟踪心率时可以自信地使用 Apple Watch Series 6 和 7;然而,在中速或更高速度跑步时必须小心。Polar H-10 可以替代临床 ECG 用于实际应用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验