Validation of HDR brachytherapy doses in the treatment of keloid scars using the egs_brachy Monte Carlo application.

作者信息

Saikkonen Aleksi, Ojala Jarkko, Sipilä Petri, Boman Eeva, Keyriläinen Jani

机构信息

Department of Physics and Astronomy, University of Turku, Vesilinnantie 5, FI-20014 Turku, Finland.

Department of Medical Physics & Department of Oncology and Radiotherapy, Turku University Hospital, Hämeentie 11, FI-20521 Turku, Finland.

出版信息

Phys Med Biol. 2023 Apr 4;68(8). doi: 10.1088/1361-6560/acc30a.

Abstract

. Radiotherapy is a well-known alternative in the treatment of keloid scars to reduce the recurrence of scars. The purpose of this study was to investigate the feasibility and accuracy of dose delivered from a high-dose-rate (HDR) afterloaders in keloid scar brachytherapy using Monte Carlo (MC) simulations and measurements.. Treatment doses and central axis dose profiles were measured using radiophotoluminescence dosimeters and radiochromic films, respectively, with two HDR afterloaders, both using an Ir-192 source, in a phantom made of solid water and polycarbonate sheets. The nominal treatment dose calculated by the AAPM Task Group No. 43 (TG-43) dose model was set to 8.5 Gy at a distance of 0.5 cm laterally from the middle of the source line located in a plastic applicator simulating a 15 cm long surgically removed scar treatment with 30 equally spaced (0.5 cm) source positions. The dose profiles were measured at three different distances from the applicator and the absolute doses at four points at different distances. MC simulations were performed using the egs_brachy, which is based on EGSnrc code system.. The measured and simulated dose profiles match well, especially at 10.0 mm (difference <1%) and 15.0 mm depths (difference <4%), and with a small dose difference at 5.0 mm depth (difference <4%). Point dose measurements agreed well in the dose maximum area (difference <7%) with the simulated dose profiles, although the largest difference near the edge of the profile was <30%. The dose differences between the TG-43 dose model and the MC simulation were small (differences <4%).. Simulated and measured dose levels at a depth of 0.5 cm showed that the nominal treatment dose can be achieved with the utilized setup. The measurement results of the absolute dose agree well with the corresponding simulation results.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验