Suppr超能文献

使用Lehfilcon A硅水凝胶水梯度隐形眼镜评估低、高隐形眼镜干眼问卷(CLDEQ - 8)评分之间的泪膜动力学:一种非侵入性方法。

Tear Film Dynamics between Low and High Contact Lens Dry Eye Disease Questionnaire (CLDEQ-8) Score with a Lehfilcon A Silicone Hydrogel Water Gradient Contact Lens: A Non-Invasive Methodology Approach.

作者信息

Capote-Puente Raúl, Bautista-Llamas María-José, Sánchez-González José-María

机构信息

Department of Physics of Condensed Matter, Optica Area, Vision Research Group (CIVIUS), Faculty of Pharmacy, University of Seville, 41012 Seville, Spain.

出版信息

Diagnostics (Basel). 2023 Mar 1;13(5):939. doi: 10.3390/diagnostics13050939.

Abstract

The purpose of this study is to evaluate the tear film dynamics between individuals with low and high Contact Lens Dry Eye Disease Questionnaire (CLDEQ-8) scores when wearing Lehfilcon A silicone hydrogel water gradient contact lenses. In this study, we implemented a longitudinal, single-location, self-comparison investigation. Variables measured included conjunctival redness, lipid layer thickness, tear meniscus height, first and mean non-invasive break-up time, CLDEQ-8, and standard patient evaluation of eye dryness (SPEED). In the second phase, participants were re-evaluated after 30 days of wearing the contact lenses to assess the tear film wearing the lenses. In a longitudinal comparison by group, we found that lipid layer thickness decreased 1.52 ± 1.38 ( < 0.01) and 0.70 ± 1.30 ( = 0.01) Guillon patterns degrees in the low and high CLDEQ-8 group, respectively. MNIBUT increased in 11.93 ± 17.93 ( < 0.01) and 7.06 ± 12.07 ( < 0.01) seconds. Finally, LOT increased in 22.19 ± 27.57 ( < 0.01) and 16.87 ± 25.09 ( < 0.01). In conclusion, this study demonstrates the effectiveness of Lehfilcon A silicone hydrogel water gradient contact lenses in improving tear film stability and reducing subjective dry eye symptoms in individuals with low and high CLDEQ-8 scores. However, it also led to an increase in conjunctival redness and a decrease in tear meniscus height.

摘要

本研究的目的是评估佩戴Lehfilcon A硅水凝胶水梯度隐形眼镜时,接触镜干眼疾病问卷(CLDEQ - 8)得分低和高的个体之间的泪膜动力学。在本研究中,我们实施了一项纵向、单中心、自身对照调查。测量的变量包括结膜充血、脂质层厚度、泪河高度、首次和平均非侵入性泪膜破裂时间、CLDEQ - 8以及标准干眼患者评估(SPEED)。在第二阶段,参与者在佩戴隐形眼镜30天后重新进行评估,以评估佩戴镜片时的泪膜情况。在按组进行的纵向比较中,我们发现,在CLDEQ - 8得分低和高的组中,脂质层厚度分别下降了1.52±1.38(<0.01)和0.70±1.30(=0.01)Guillon模式度数。平均非侵入性泪膜破裂时间分别增加了11.93±17.93(<0.01)和7.06±12.07(<0.01)秒。最后,泪河长度分别增加了22.19±27.57(<0.01)和16.87±25.09(<0.01)。总之,本研究证明了Lehfilcon A硅水凝胶水梯度隐形眼镜在改善CLDEQ - 8得分低和高的个体的泪膜稳定性以及减轻主观干眼症状方面的有效性。然而,它也导致结膜充血增加和泪河高度降低。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/58ed/10001148/e024c18d7f82/diagnostics-13-00939-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验