Wang Dandan, Liu Chunlu, Guan Weichen, Lu Ziyi, Zhao Yinying, Zhao Yune
Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China.
National Clinical Research Center for Ocular Disease, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China.
Front Med (Lausanne). 2023 Feb 23;10:1094966. doi: 10.3389/fmed.2023.1094966. eCollection 2023.
To explore the effect of corneal spherical aberration on the visual acuity and visual quality of eyes implanted with the TECNIS Symfony intraocular lens (IOL).
A total of 43 patients with age-related cataract (60 eyes) undergoing phacoemulsification and TECNIS Symfony IOL implantation were enrolled in this study. The uncorrected distance (UDVA), intermediate (UIVA), near visual acuity (UNVA), corrected distance visual acuity (CDVA), contrast sensitivity, and ocular spherical aberration were recorded 3 months after surgery. Preoperative and postoperative corneal spherical aberration were also measured using the iTrace device. Objective scattering index (OSI), modulation transfer function cut-off frequency (MTF cut-off), and Strehl ratio (SR) were measured by the Optical Quality Analyzing System. Catquest-9SF questionnaire were applied too. Spearman's correlation analysis was used to evaluate the relationship between spherical aberration and visual quality parameters.
Patients were satisfied with their postoperatively visual quality. And the postoperative logMAR UDVA, UIVA, UNVA, and CDVA was 0.05 ± 0.07, 0.04 ± 0.06, 0.15 ± 0.07, and 0.03 ± 0.05, respectively. The mean preoperative corneal spherical aberration was 0.24 ± 0.10 μm, which is the only factor influencing postoperatively UNVA, and it was negatively correlated with UNVA and glare contrast sensitivity under 18 cpd (cycle/degree, cpd) spatial frequency ( = -0.403, -0.300, -0.360; all < 0.05). Additionally, the greater the residual spherical aberration of the cornea, the better the near vision after operation. The mean postoperative ocular spherical aberration was -0.03 ± 0.07 μm, it was not correlated with visual acuity, contrast sensitivity, and visual quality (all > 0.05).
Preoperative positive spherical aberration can benefit near vision while decrease contrast sensitivities at high spatial frequencies when implanted with the TECNIS Symfony IOL.
探讨角膜球差对植入TECNIS Symfony人工晶状体(IOL)眼的视力和视觉质量的影响。
本研究共纳入43例年龄相关性白内障患者(60只眼),均接受了白内障超声乳化吸除联合TECNIS Symfony IOL植入术。术后3个月记录未矫正远视力(UDVA)、中视力(UIVA)、近视力(UNVA)、矫正远视力(CDVA)、对比敏感度和眼球差。术前和术后均使用iTrace设备测量角膜球差。采用光学质量分析系统测量客观散射指数(OSI)、调制传递函数截止频率(MTF截止)和斯特列尔比(SR)。同时应用Catquest-9SF问卷。采用Spearman相关性分析评估球差与视觉质量参数之间的关系。
患者对术后视觉质量满意。术后logMAR UDVA、UIVA、UNVA和CDVA分别为0.05±0.07、0.04±0.06、0.15±0.07和0.03±0.05。术前平均角膜球差为0.24±0.10μm,这是影响术后UNVA的唯一因素,且与UNVA以及18周/度(cpd)空间频率下的眩光对比敏感度呈负相关(r=-0.403、-0.300、-0.360;均P<0.05)。此外,角膜残余球差越大,术后近视力越好。术后平均眼球差为-0.03±0.07μm,与视力、对比敏感度和视觉质量均无相关性(均P>0.05)。
植入TECNIS Symfony IOL时,术前正球差有助于近视力,但会降低高空间频率下的对比敏感度。