Liu Xin, Song Xiaohui, Wang Wei, Zhu Yanan, Lyu Danni, Shentu Xingchao, Chen Peiqing, Yu Yibo, Yao Ke
Eye Center, The Second Affiliated Hospital of College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310000, China.
J Ophthalmol. 2019 Sep 23;2019:5815040. doi: 10.1155/2019/5815040. eCollection 2019.
To compare the clinical outcomes of echelette extended range of vision (ERV) and diffractive bifocal intraocular lenses (IOLs).
This is a prospective, consecutive, nonrandomized clinical trial. Seventy-three eligible patients (109 eyes) received the implantation of echelette ERV IOL (Tecnis Symfony ZXR00) or diffractive bifocal IOL (Tecnis ZMB00). 1 week, 1 month, and 3 months after surgery, visual acuities at different distances were examined. At 3 months, defocus curves, contrast sensitivities (CSs) with and without glare, optic path difference (OPD) scans, and questionnaires were evaluated. Regression analyses were applied to discover influence factors on postoperative vision.
ZXR00 showed better distance ( < 0.05) and intermediate ( < 0.001) visual acuities, while ZMB00 was better at distance-corrected near visual acuity ( < 0.001). Multivariate analyses indicated that worse intermediate ( < 0.001) and near vision (=0.013) of ZMB00 might occur in patients with longer axial length. ZXR00 demonstrated smoother defocus curve and higher CSs. Superior modulation transfer function (MTF) and higher Strehl ratio ( < 0.05) were shown in ZXR00. In questionnaire evaluation, ZXR00 received better outcomes in self-reported vision, Visual Function-14 (VF-14) questionnaire, Quality of Vision (QoV) questionnaire, satisfaction, and recommendation grades. Spectacle dependence did not differ between ZXR00 and ZMB00 statistically.
ZXR00 proved to be remarkable in distance and intermediate vision, defocus curve smoothness, CSs, and visual comfort, while ZMB00 achieved better near vision. ZXR00 may attain better near vision if postoperative SE remains slightly negative. Patients with relatively longer axial length might receive less favorable intermediate and near vision after ZMB00 implantation. This trial is registered with ChiCTR-ONC-17011119.
比较小阶梯光栅扩展视程(ERV)人工晶状体(IOL)和衍射双焦点人工晶状体的临床效果。
这是一项前瞻性、连续性、非随机临床试验。73例符合条件的患者(109只眼)接受了小阶梯光栅ERV人工晶状体(Tecnis Symfony ZXR00)或衍射双焦点人工晶状体(Tecnis ZMB00)植入术。术后1周、1个月和3个月,检查不同距离的视力。在3个月时,评估散焦曲线、有无眩光时的对比敏感度(CS)、光程差(OPD)扫描及问卷调查结果。应用回归分析来发现影响术后视力的因素。
ZXR00在远视力(P<0.05)和中视力(P<0.001)方面表现更佳,而ZMB00在距离矫正近视力方面更优(P<0.001)。多因素分析表明,眼轴较长的患者植入ZMB00后可能出现较差的中视力(P<0.001)和近视力(P=0.013)。ZXR00显示出更平滑的散焦曲线和更高的对比敏感度。ZXR00的调制传递函数(MTF)更佳,斯特列尔比更高(P<0.05)。在问卷调查评估中,ZXR00在自我报告视力、视觉功能-14(VF-14)问卷、视觉质量(QoV)问卷、满意度及推荐等级方面获得更好的结果。ZXR00和ZMB00在眼镜依赖方面无统计学差异。
ZXR00在远视力和中视力、散焦曲线平滑度、对比敏感度及视觉舒适度方面表现出色,而ZMB00的近视力更佳。如果术后球镜度数(SE)仍略为负值,ZXR00可能获得更好的近视力。眼轴相对较长的患者植入ZMB00后,中视力和近视力可能较差。本试验已在中国临床试验注册中心注册,注册号为ChiCTR-ONC-17011119。