检测中尿液污染导致血清结果异常 1 例

A Case of Abnormal Results Caused by Urine Contamination in Serum During Detection.

出版信息

Clin Lab. 2023 Mar 1;69(3). doi: 10.7754/Clin.Lab.2022.220608.

Abstract

BACKGROUND

Unqualified samples directly affect the accuracy of test results in clinical laboratory. Timely and accurate identification of unqualified specimens can avoid the occurrence of medical adverse events.

METHODS

This study reported a case of abnormal results caused by urine carrying contamination in serum during detection.

RESULTS

During the testing process, improper operation of laboratory staff led to serum contamination with urine, which affected the accuracy of the test results.

CONCLUSIONS

In addition to the pre-inspection stage, all laboratories should also pay attention to the quality control of sample during the inspection, so as to ensure the accuracy of the results and medical safety.

摘要

背景

不合格样本直接影响临床实验室检验结果的准确性。及时准确地识别不合格标本可以避免医疗不良事件的发生。

方法

本研究报告了一例在检测过程中尿液污染血清导致结果异常的案例。

结果

在检测过程中,实验室工作人员操作不当导致血清被尿液污染,影响了检测结果的准确性。

结论

除了预检验阶段,所有实验室还应在检验过程中注意样本的质量控制,以确保结果的准确性和医疗安全。