Suppr超能文献

基于 HFman 探针的环介导等温扩增法和手指驱动微流控芯片快速检测尿液中的 BK 病毒。

Rapid point-of-care detection of BK virus in urine by an HFman probe-based loop-mediated isothermal amplification assay and a finger-driven microfluidic chip.

机构信息

Shanghai Public Health Clinical Center, Shanghai, China.

Nantong Third Hospital Affiliated to Nantong University, Nantong, China.

出版信息

PeerJ. 2023 Mar 8;11:e14943. doi: 10.7717/peerj.14943. eCollection 2023.

Abstract

BACKGROUND

BK virus (BKV)-associated nephropathy (BKVN) is one of the leading causes of renal dysfunction and graft loss in renal transplant recipients. Early monitoring of BKV in urine is crucial to minimize the deleterious effects caused by this virus on preservation of graft function.

METHODS

We report a simple, rapid, sensitive loop-mediated isothermal amplification (LAMP) assay using an HFman probe for detecting BKV in urine. To evaluate the performance of the assay, a comparison of the HFman probe-based LAMP (HF-LAMP) assay with two qPCR assays was performed using urine samples from 132 HIV-1 infected individuals. We further evaluated the performance of HF-LAMP directly using the urine samples from these HIV-1 infected individuals and 30 kidney transplant recipients without DNA extraction. Furthermore, we combined the HF-LAMP assay with a portable finger-driven microfluidic chip for point-of-care testing (POCT).

RESULTS

The assay has high specificity and sensitivity with a limit of detection (LOD) of 12 copies/reaction and can be completed within 30 min. When the DNA was extracted, the HF-LAMP assay showed an equivalent and potentially even higher sensitivity (93.5%) than the qPCR assays (74.2-87.1%) for 132 urine samples from HIV-1 infected individuals. The HF-LAMP assay can be applied in an extraction-free format and can be completed within 45 min using a simple heat block. Although some decreased performance was seen on urine samples from HIV-1 infected individuals, the sensitivity, specificity, and accuracy of the extraction-free BKV HF-LAMP assay were 95%, 100%, and 96.7% for 30 clinical urine samples from kidney transplant recipients, respectively.

CONCLUSION

The assay has high specificity and sensitivity. Combined with a portable finger-driven microfluidic chip for easy detection, this method shows great potential for POCT detection of BKV.

摘要

背景

BK 病毒(BKV)相关性肾病(BKVN)是导致肾移植受者肾功能障碍和移植物丢失的主要原因之一。早期监测尿液中的 BKV 对于最大限度地减少该病毒对移植物功能保存的有害影响至关重要。

方法

我们报告了一种使用 HFman 探针的简单、快速、灵敏的环介导等温扩增(LAMP)检测方法,用于检测尿液中的 BKV。为了评估该检测方法的性能,我们使用来自 132 名 HIV-1 感染个体的尿液样本,对 HFman 探针为基础的 LAMP(HF-LAMP)检测与两种 qPCR 检测方法进行了比较。我们进一步在未提取 DNA 的情况下,直接使用来自这些 HIV-1 感染个体的尿液样本和 30 名肾移植受者的尿液样本评估了 HF-LAMP 的性能。此外,我们将 HF-LAMP 检测方法与便携式手指驱动微流控芯片相结合,用于即时检测(POCT)。

结果

该检测方法具有高特异性和灵敏度,检测限(LOD)为 12 拷贝/反应,可在 30 分钟内完成。当提取 DNA 时,HF-LAMP 检测在对 132 份来自 HIV-1 感染个体的尿液样本的检测中,显示出与 qPCR 检测相当甚至更高的灵敏度(93.5%比 74.2-87.1%)。HF-LAMP 检测可以在无需提取的情况下进行,并且可以在简单的热块中在 45 分钟内完成。尽管在 HIV-1 感染个体的尿液样本中检测性能有所下降,但提取自由的 BKV HF-LAMP 检测对 30 份肾移植受者的临床尿液样本的灵敏度、特异性和准确性分别为 95%、100%和 96.7%。

结论

该检测方法具有高特异性和灵敏度。与便携式手指驱动微流控芯片相结合,该方法在 BKV 的 POCT 检测方面具有很大的潜力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验