Suppr超能文献

Utility of Substrate Mapping Using Extrasystole to Localise Comprehensive Ventricular Tachycardia Circuits: Results From Intra-operative Mapping Studies.

作者信息

Mumtaz Maroosh, Downar Eugene, Kawada Satoshi, Zammit-Burg Melanie, Anderson Robert, Massé Stéphane, Nair Madhav Krishna Kumar, Nanthakumar Jared, Ghauri Fateh Muhammad, Sánchez Andreu Porta-, Bhaskaran Abhishek

机构信息

Peter Munk Cardiac Centre, Toronto General Hospital, University Health Network Toronto, Ontario, Canada; Department of Medicine, Cardiology, University of Toronto, Ontario, Canada.

Peter Munk Cardiac Centre, Toronto General Hospital, University Health Network Toronto, Ontario, Canada.

出版信息

Can J Cardiol. 2023 Jul;39(7):912-921. doi: 10.1016/j.cjca.2023.02.074. Epub 2023 Mar 12.

Abstract

BACKGROUND

Substrate mapping-based identification of all ventricular tachycardia (VT) circuits (diastolic activation), including partial and complete diastolic circuits in clinical and nonclinical VT, could be beneficial in guiding VT ablation to prevent VT recurrence. The utility of extrasystole induced late potentials has not been compared with late potentials in sinus rhythm (SR) and right ventricular pacing (RVp).

METHODS

Intraoperative simultaneous panoramic endocardial mapping of 21 VTs in 16 ischemic heart disease patients was performed with the use of a 112-bipole endocardial balloon. The decrement of near-field electrogram later than surface QRS during extrasystole (eLP) was studied.

RESULTS

Patients had a mean age of 52 ± 9 years and were predominantly (75%) male. The mean sensitivity of eLP (0.75 [95% confidence interval [CI] 0.72-0.78]) to detect VT circuits was better than SR (0.33 [0.30-0.36]; P < 0.001) and RVp (0.36 [0.33-0.39]; P < 0.001) without significant differences in specificity, eLP (0.77 [0.74-0.81], SR (0.82 [0.80-0.84]; P = 0.23), and RVp (0.81 [0.78-0.83]; P = 0.11). Both negative (NPV) and positivie (PPV) predictive values were significantly better for eLP mapping. The mean NPV was 0.77 (95% CI 0.74-0.81), 0.57 (0.55-0.59), and 0.58 (0.55-0.61) for eLP, SR, and RVp, respectively (P < 0.0001). PPV was 0.75 (95% CI 0.72-0.78), 0.63 (0.59-0.67), and 0.63 (0.59-0.67) for eLP, SR, and RVp, respectively (P < 0.001). Overall diagnostic performance (area under the receiver operating characteristic curve) was significantly better for eLP (0.85 [95% CI 0.80-0.90] compared with SR (0.63 [0.56-0.72]; P < 0.001) or RVp (0.61 [0.52-0.74]; P < 0.001).

CONCLUSIONS

Evoked late potential mapping is a better tool to detect comprehensive diastolic circuits activated during VT, compared with eLP mapping in sinus rhythm or RV pacing.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验