临床正常比格犬使用非离子型造影剂进行脑灌注计算机断层扫描的最佳注射速率和导管尺寸

Optimal injection rate and catheter size for brain perfusion computed tomography using non-ionic contrast medium in clinically normal Beagles.

作者信息

Choi Wonyoung, Ko Jaeun, Kim Jayon, Cho Chang-Hyeon, Kim Jaehwan, Eom Kidong

出版信息

Am J Vet Res. 2023 Mar 20;84(5). doi: 10.2460/ajvr.22.12.0211. Print 2023 May 1.

Abstract

OBJECTIVE

To evaluate the effects of contrast medium injection rates and intravenous injection catheter sizes on the time-density curve (TDC) of brain perfusion computed tomography (PCT) images in clinically normal Beagles and provide a reference range for the perfusion parameters for clinical application of PCT in veterinary medicine.

ANIMALS

5 healthy, sexually intact male Beagles.

PROCEDURES

All dogs underwent general anesthesia for PCT. Contrast medium (350 mg I/kg) was injected at 3 different injection rates (2, 3, and 4 mL/second) and with 2 sizes of an intravenous catheter (20-gauge and 24-gauge). The rostral cerebral artery and dorsal sagittal sinus were selected as the regions of interest of the TDC. Initiation time of arterial inflow (ta), venous outflow (tv), peak time of arterial enhancement (Tap), and the peak time of venous enhancement (Tvp), were measured, and the difference between Tap and tv (Tap-tv) and between Tap and ta (Tap-ta) was calculated.

RESULTS

Both Tap-tv and Tap-ta were significantly (P < .05) shorter at the rate of 3 mL/second than at 2 mL/second with the 24-gauge catheter. However, there was no significant difference according to catheter sizes. Particularly, a 4 mL/second injection rate using a 24-gauge catheter mostly resulted in contrast medium leakage and catheter rupture.

CLINICAL RELEVANCE

CONTRAST MEDIUM INJECTION: At a rate of 3 mL/second and with a 24-gauge catheter ensures optimal image acquisition and stable contrast medium injection in brain PCT for small dogs. PCT may be useful for diagnosing cerebrovascular events and hemodynamic changes in small dogs.

摘要

目的

评估造影剂注射速率和静脉注射导管尺寸对临床正常比格犬脑灌注计算机断层扫描(PCT)图像时间-密度曲线(TDC)的影响,并为PCT在兽医学临床应用中的灌注参数提供参考范围。

动物

5只健康、未绝育的雄性比格犬。

方法

所有犬只在PCT检查时接受全身麻醉。以3种不同的注射速率(2、3和4 mL/秒)以及2种尺寸的静脉导管(20号和24号)注射造影剂(350 mg I/kg)。选择大脑前动脉和矢状窦背侧作为TDC的感兴趣区域。测量动脉流入起始时间(ta)、静脉流出时间(tv)、动脉强化峰值时间(Tap)和静脉强化峰值时间(Tvp),并计算Tap与tv之间的差值(Tap-tv)以及Tap与ta之间的差值(Tap-ta)。

结果

使用24号导管时,3 mL/秒注射速率下的Tap-tv和Tap-ta均显著(P < 0.05)短于2 mL/秒注射速率时的结果。然而,根据导管尺寸没有显著差异。特别是,使用24号导管以4 mL/秒的注射速率大多会导致造影剂渗漏和导管破裂。

临床意义

造影剂注射:对于小型犬的脑PCT检查,以3 mL/秒的速率和24号导管可确保最佳图像采集和稳定的造影剂注射。PCT可能有助于诊断小型犬的脑血管事件和血流动力学变化。