两种不同电脑控制局部麻醉注射系统在儿童中应用的对比研究:一项随机临床试验。

Comparative study of two different computer-controlled local anesthesia injection systems in children: a randomized clinical trial.

机构信息

Department of Pediatric and Community Dentistry, Faculty of Dental Medicine, Saint Joseph University, Beirut, Lebanon.

Department of Fixed Prosthodontics, Faculty of Dental Medicine, Saint Joseph University, Beirut, Lebanon.

出版信息

Eur Arch Paediatr Dent. 2023 Jun;24(3):417-423. doi: 10.1007/s40368-023-00793-3. Epub 2023 Mar 18.

Abstract

PURPOSE

To compare pain perception associated with two computer-controlled local anesthesia devices, the WAND™ STA (Milestone Scientific Inc., Livingston, NJ, USA) and the Calaject (Rønvig dental MFG, Daugaard, Denmark) in young children.

METHODS

A split-mouth randomized clinical trial comprising 30 patients, aged 6-12 years, received randomly, in two separate sessions, a local anesthesia injection in the maxillary using either the wand STA or the Calaject. Pain perception was evaluated using the patient's heart rate, an 11-point numerical scale (NRS), and the Sound, Eye, and Motor (SEM) body movements. Statistical difference was set at p = 0.05. Repeated measures analysis of variance were conducted to compare the mean pulse for Calaject and STA at different times. It was followed by univariate analysis and Bonferroni multiple comparisons tests. Wilcoxon tests were performed to compare NRS, SEM, and injection duration between Calaject and STA.

RESULTS

There was no significant statistical difference between Calaject and STA in pulse rate before injection (p = 0.720), during injection (p = 0.767), and after injection (p = 0.757). The mean NRS score was significantly greater with STA in comparison with Calaject (p = 0.017). The mean SEM score was also significantly greater with STA in comparison with Calaject (p = 0.002). However, the mean duration was significantly longer with Calaject (p = 0.001).

CONCLUSIONS

Calaject was more effective than STA in reducing pain perception associated with periapical injection in young children.

摘要

目的

比较两种计算机控制局部麻醉设备(美国密尔沃基市里程碑科学公司的 WAND™ STA 和丹麦 Rønvig dental MFG 的 Calaject)在幼儿中引起的疼痛感知。

方法

一项包括 30 名 6-12 岁患者的分口随机临床试验,在两个单独的治疗中,分别随机使用 wand STA 或 Calaject 在上颌进行局部麻醉注射。使用患者的心率、11 点数字评分(NRS)和声音、眼睛和运动(SEM)身体运动来评估疼痛感知。统计差异设定为 p=0.05。采用重复测量方差分析比较不同时间点 Calaject 和 STA 的平均脉搏。然后进行单变量分析和 Bonferroni 多重比较检验。采用 Wilcoxon 检验比较 Calaject 和 STA 之间的 NRS、SEM 和注射持续时间。

结果

在注射前(p=0.720)、注射期间(p=0.767)和注射后(p=0.757),Calaject 和 STA 的脉搏率之间没有统计学差异。与 Calaject 相比,STA 的平均 NRS 评分显著更高(p=0.017)。与 Calaject 相比,STA 的平均 SEM 评分也显著更高(p=0.002)。然而,Calaject 的平均持续时间明显更长(p=0.001)。

结论

与 STA 相比,Calaject 能更有效地减轻幼儿根尖注射引起的疼痛感知。