3D打印经皮导向板在股骨颈骨折闭合复位空心螺钉内固定中的应用

[Application of 3D printing percutaneous guide plate in closed reduction and cannulated screw internal fixation of femoral neck fracture].

作者信息

Wang Qing-Ze, Luo Ming-Xing, Zeng Shuai, Bao Jun-Guo, Luo Wen-Li, Yuan Kai-Zong, Lao Li-Feng

机构信息

Department of Orthopaedics, Ningbo Hangzhou Bay Hospital, Ningbo 315000, Zhejiang, China.

出版信息

Zhongguo Gu Shang. 2023 Mar 25;36(3):209-15. doi: 10.12200/j.issn.1003-0034.2023.03.003.

Abstract

OBJECTIVE

To investigate the application of 3D printing percutaneous surgical guide plate in closed reduction and cannulated screw internal fixation of femoral neck fracture.

METHODS

The clinical data of 12 patients with femoral neck fracture from March 2019 to March 2022 were retrospectively analyzed. Patients were divided into observation group and control group according to different operation plans, with 6 cases in each group. The observation group received percutaneous operation guide plate assisted closed reduction and hollow screw internal fixation, while the control group received closed reduction and hollow compression screw internal fixation. The operation time, intraoperative blood loss, fluoroscopy times, and Kirschner needle puncture times were compared between two groups. The location of screws were recordedon postoperative X-ray films, follow-up time, time of complete fracture healing, Harris score of hip joint and the incidence of complications were recorded on postoperative X-ray films.

RESULTS

The operation time of observation group (32.17±6.18) min was shorter than that of control group (53.83±7.31) min (<0.05). The amount of intraoperative bleeding in the observation group (18.33±2.94) ml was less than that in the control group (38.17±5.56) ml(<0.05). The times of fluoroscopy in the observation group (7.50±1.05) were less than those in the control group (21.00±4.82) (<0.05). The number of Kirschner needle punctures (8.00±0.63) in observation group was less than that in control group (32.67±3.08) (<0.05). The follow-up time was(12.88±0.74) months in observation group and (12.83±0.72) months in control group, there was no significant difference between two groups (>0.05). One year after operation, Harris score of hip joint in the observation group was(82.00±4.52) points, while that in the control group was(81.00±3.41) points, there was no significant difference between two groups(>0.05). The time of complete fracture healing in the observation group was (7.50±1.05) months, while that in the control group was (7.67±1.21) months, there was no significant difference between two groups(>0.05). The parallelism of the screws in the observation group was (0.50±0.11) ° and (0.76±0.15) °, which were lower than that in the control group (1.57±0.31) ° and (1.87±0.21) ° (<0.05). The screw distribution area ratio (0.13±0.02) cm2 in the observation group was higher than that in the control group (0.08±0.01) cm2 (<0.05). No complications such as necrosis of femoral head, nonunion of fracture, shortening of femoral neck and withdrawal of internal fixation occurred in both groups.

CONCLUSION

The application of 3D printing percutaneous surgical guide plate improves the accuracy and safety of closed reduction and cannulated screw internal fixation for femoral neck fracture. It has the advantages of minimally invasive, reducing radiation exposure, fast and accurate, shortening the operation time and reducing intraoperative bleeding.

摘要

目的

探讨3D打印经皮手术导板在股骨颈骨折闭合复位空心螺钉内固定中的应用。

方法

回顾性分析2019年3月至2022年3月收治的12例股骨颈骨折患者的临床资料。根据不同手术方案将患者分为观察组和对照组,每组6例。观察组采用经皮手术导板辅助闭合复位空心螺钉内固定,对照组采用闭合复位空心加压螺钉内固定。比较两组手术时间、术中出血量、透视次数及克氏针穿刺次数。术后X线片记录螺钉位置,记录随访时间、骨折完全愈合时间、髋关节Harris评分及并发症发生率。

结果

观察组手术时间(32.17±6.18)min短于对照组(53.83±7.31)min(<0.05)。观察组术中出血量(18.33±2.94)ml少于对照组(38.17±5.56)ml(<0.05)。观察组透视次数(7.50±1.05)次少于对照组(21.00±4.82)次(<0.05)。观察组克氏针穿刺次数(8.00±0.63)次少于对照组(32.67±3.08)次(<0.05)。观察组随访时间为(12.88±0.74)个月,对照组为(12.83±0.72)个月,两组比较差异无统计学意义(>0.05)。术后1年,观察组髋关节Harris评分为(82.00±4.52)分,对照组为(81.00±3.41)分,两组比较差异无统计学意义(>0.05)。观察组骨折完全愈合时间为(7.50±1.05)个月,对照组为(7.67±1.21)个月,两组比较差异无统计学意义(>0.05)。观察组螺钉平行度为(0.50±0.11)°和(0.76±0.15)°,低于对照组的(1.57±0.31)°和(1.87±0.21)°(<0.05)。观察组螺钉分布面积比为(0.13±0.02)cm²高于对照组的(0.08±0.01)cm²(<0.05)。两组均未发生股骨头坏死、骨折不愈合、股骨颈缩短及内固定物退出等并发症。

结论

3D打印经皮手术导板的应用提高了股骨颈骨折闭合复位空心螺钉内固定的准确性和安全性。具有微创、减少辐射暴露、快速准确、缩短手术时间及减少术中出血等优点。