Rizwan Amna, Javaid Rana Muhammad Mohsin, Latif Sidrah, Sarwar Muhammad Suhail, Khan Asad Aslam
Amna Rizwan, Eye Unit-III, Mayo Hospital Lahore, Pakistan.
Rana Muhammad Mohsin Javaid, Eye Unit-III, Mayo Hospital Lahore, Pakistan.
Pak J Med Sci. 2023 Mar-Apr;39(2):439-443. doi: 10.12669/pjms.39.2.6243.
To compare the effectiveness of fluid-air exchange with silicone oil-fluid exchange in reducing the residual silicone oil (SO) droplets after the removal of SO.
This was a prospective, quasi-experimental study conducted from October 2021 to February 2022 at Eye Unit-III, COAVS, Mayo Hospital, Lahore. Sixty-one patients with siliconized eyes underwent removal of SO with two different techniques and were divided into fluid-air exchange and oil-fluid exchange groups. To quantify the residual silicone droplets objectively, B-scan echographic images were analyzed within seven days of surgery. Silicone oil index (SOI) which is the amount of residual SO droplets/vitreal area in the images was calculated with the help of imagej software.
The residual SOI of the fluid-air exchange group (0.99 ± 1.76%) was significantly lower than the oil-fluid exchange group (3.25 ± 3.85%). The SOI is positively correlated with the duration of tamponade, preoperative intraocular- pressure and axial length. Persistent IOP elevation post-operatively was seen in 16.67% individuals in the fluid-air exchange group and 54.8% individuals in the oil-fluid exchange group.
Fluid-air exchange group was found to be superior in reducing residual SO droplets than the oil-fluid exchange group.
比较液体-空气交换与硅油-液体交换在硅油取出后减少残留硅油滴的效果。
这是一项前瞻性、准实验性研究,于2021年10月至2022年2月在拉合尔梅奥医院COAVS眼科三室进行。61例硅油化眼患者采用两种不同技术取出硅油,并分为液体-空气交换组和油-液体交换组。为了客观量化残留硅油滴,在手术后7天内分析B超图像。借助ImageJ软件计算硅油指数(SOI),即图像中残留硅油滴的数量/玻璃体面积。
液体-空气交换组的残留SOI(0.99±1.76%)显著低于油-液体交换组(3.25±3.85%)。SOI与填塞时间、术前眼压和眼轴长度呈正相关。液体-空气交换组16.67%的个体术后眼压持续升高,油-液体交换组为54.8%。
发现液体-空气交换组在减少残留硅油滴方面优于油-液体交换组。