Suppr超能文献

电化学法测定实际样品中磷酸氯喹的研究——二间苯二甲酸-1,10-菲咯啉钴(II)修饰玻碳电极的应用。

Electrochemical Determination of Chloroquine Phosphate in Real Samples Using a Diresorcinate-1,10-phenanthrolinecobalt(II)-Modified Glassy Carbon Electrode.

机构信息

Department of Chemistry, College of Natural and Computational Sciences, Debre Markos University, 269, Debre Markos, Ethiopia.

Department of Chemistry, College of Science, Bahir Dar University, 79, Bahir Dar, Ethiopia.

出版信息

ChemistryOpen. 2023 Mar;12(3):e202300004. doi: 10.1002/open.202300004.

Abstract

Chloroquine phosphate (CQP) is used for malaria treatment. As it is facing increasing resistance, it needs continuous monitoring using sensitive and specific detection methods. In this work, a voltammetric sensor was prepared by electropolymerization of a diresorcinate-1,10-phenanthrolinecobalt(II) complex on a glassy carbon electrode (poly(DHRPCo)/GCE) which was followingly characterized. Compared with a bare GCE, CQP showed single well shaped irreversible oxidative peak at the poly(DHRPCo)/GCE. The peak current showed excellent linearity with CQP concentration in the range of 0.005-300.0 μm with a detection limit of 0.39 nm. The response of CQP at poly(DHRPCo)/GCE was not influenced by the presence of amoxicillin, ciprofloxacillin and paracetamol in addition to its high stability and reproducibility. It was applied for detection of CQP in various real samples, including three brands of tablets, human blood serum, and urine samples. The detected amount in tablets were in the range 98.4-103.2 % of their labeled value. Spike recovery results in human blood serum, urine, and tablet samples were 99.35-100.28 %, 99.03-100.32 %, and 98.40-100.41 %, respectively. Interference recovery results with less than 4.60 % error, the lower limit of detection and the wider dynamic range than most of the previously reported methods validate the potential applicability of the proposed method for CQP determination in various real samples with complex matrices.

摘要

磷酸氯喹(CQP)用于治疗疟疾。由于它面临着越来越多的耐药性,因此需要使用敏感和特异的检测方法进行持续监测。在这项工作中,通过在玻碳电极(poly(DHRPCo)/GCE)上聚合二邻苯二甲酰亚氨基-1,10-邻菲咯啉钴(II)配合物,制备了一种伏安传感器,并对其进行了表征。与裸 GCE 相比,在 poly(DHRPCo)/GCE 上 CQP 显示出单一的、形状良好的不可逆氧化峰。在 0.005-300.0 μm 的范围内,CQP 浓度与峰电流表现出良好的线性关系,检测限为 0.39 nm。poly(DHRPCo)/GCE 对 CQP 的响应不受阿莫西林、环丙沙星和扑热息痛的存在影响,并且具有高稳定性和重现性。它被应用于各种实际样品中 CQP 的检测,包括三种品牌的片剂、人血清和尿液样品。片剂中的检测量在其标记值的 98.4-103.2%范围内。人血清、尿液和片剂样品的加标回收率分别为 99.35-100.28%、99.03-100.32%和 98.40-100.41%。干扰恢复结果误差小于 4.60%,检测下限和更宽的动态范围比大多数先前报道的方法更宽,验证了该方法在各种复杂基质的实际样品中测定 CQP 的潜在适用性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5dcc/10041376/2c858d81218d/OPEN-12-e202300004-g001.jpg