Department of Emergency Medicine, University of California, San Diego, San Diego, California.
J Emerg Med. 2023 Apr;64(4):464-470. doi: 10.1016/j.jemermed.2022.12.003. Epub 2023 Mar 27.
Spit restraint devices, also referred to as spit hoods, spit masks, or spit socks, are used by law enforcement and medical personnel to minimize transmission of communicable disease from bodily fluids from agitated individuals. Several lawsuits have implicated spit restraint devices as contributing to the death of individuals who are physically restrained by means of asphyxiation due to saturation of the mesh restraint device with saliva.
This study aims to evaluate whether a saturated spit restraint device has any clinically significant effects on the ventilatory or circulatory parameters of healthy adult subjects.
Subjects wore a spit restraint device dampened with 0.5% carboxymethylcellulose, an artificial saliva. Baseline vitals were taken, and a wet spit restraint device was then placed over the subject's head, and repeat measurements were taken at 10, 20, 30, and 45 min. A second spit restraint device was placed 15 min after the first. Measurements at 10, 20, 30, and 45 min were compared with baseline using paired t-tests.
The mean age of 10 subjects was 33.8 years, and 50% were female. There was no significant difference between baseline and while wearing the spit sock for 10, 20, 30, and 45 min for the measured parameters including heart rate, oxygen saturation, end-tidal CO, respiratory rate, or blood pressure. No subject indicated respiratory distress or had to terminate the study.
In healthy adult subjects, there were no statistically or clinically significant differences in ventilatory or circulatory parameters while wearing the saturated spit restraint.
唾液约束装置,也被称为唾液罩、唾液面具或唾液袜子,被执法人员和医务人员用于减少来自激动个体的体液传播传染病。几项诉讼将唾液约束装置与因唾液饱和而导致的网格约束装置窒息导致个体死亡联系起来。
本研究旨在评估饱和的唾液约束装置是否对健康成年受试者的呼吸或循环参数有任何临床显著影响。
受试者佩戴用 0.5%羧甲基纤维素(一种人工唾液)润湿的唾液约束装置。记录基本生命体征,然后将湿唾液约束装置放在受试者头上,在 10、20、30 和 45 分钟时重复测量。在第一次之后 15 分钟放置第二个唾液约束装置。使用配对 t 检验将 10、20、30 和 45 分钟的测量值与基线进行比较。
10 名受试者的平均年龄为 33.8 岁,其中 50%为女性。在佩戴唾液套 10、20、30 和 45 分钟期间,测量的参数包括心率、血氧饱和度、呼气末 CO、呼吸频率或血压,与基线相比没有显著差异。没有受试者表示呼吸困难或必须终止研究。
在健康成年受试者中,佩戴饱和唾液约束装置时,呼吸或循环参数没有统计学或临床显著差异。