From the Biomedical Engineering, California Polytechnical Institute, San Luis Obispo, CA.
Emergency Medicine and Medical Toxicology, University of Texas Southwestern Medical Center, Dallas, TX.
Am J Forensic Med Pathol. 2024 Mar 1;45(1):10-14. doi: 10.1097/PAF.0000000000000877. Epub 2023 Aug 14.
Spit hoods are used by law enforcement, officers in correctional facilities, and medical personnel during the restraint of agitated subjects that are actively spitting to prevent the transmission of droplet-transmitted pathogens. We could find no studies reporting on the time course of normal breathing to clear saliva from such a saturated spit hood. We purchased samples of 3 popular spit hood models and applied a section over the output of a pneumatic test system. We used a digital anemometer, digital manometer, and an inline controllable fan for back pressure and flow. The pressure was 3 mm Hg to match quiet breathing. The tested area was saturated with artificial saliva, and air pressure was applied while we recorded the pressure and airflow. Within 5 seconds, the spit hoods all cleared sufficient artificial saliva to allow 1 m/s of airflow, which exceeds that of an N95 mask with similar pressure. Commonly used spit hoods offer very low resistance to breathing even after being initially saturated with artificial saliva. Our results do not support the hypothesis that a saliva-filled spit hood might contribute to death.
口咽通气道在执法部门、惩教设施官员和医务人员对正在积极吐口水的激动患者进行约束时使用,以防止飞沫传播病原体的传播。我们没有找到任何研究报告表明,从如此饱和的口咽通气道中清除唾液需要多长时间。我们购买了 3 种流行的口咽通气道模型的样本,并将其应用于气动测试系统的输出端。我们使用数字风速计、数字压力计和内置可控风扇来提供背压和流量。压力为 3 毫米汞柱,与安静呼吸相匹配。测试区域充满了人工唾液,我们在施加气压的同时记录压力和气流。在 5 秒内,口咽通气道都清除了足够的人工唾液,以允许 1 米/秒的气流,超过了具有类似压力的 N95 口罩的气流。即使最初被人工唾液饱和,常用的口咽通气道对呼吸的阻力也非常低。我们的结果不支持口咽通气道充满唾液可能导致死亡的假设。