Department of Paediatrics, Olabisi Onabanjo University Teaching Hospital, Sagamu, Ogun State, Nigeria.
West Afr J Med. 2023 Mar 31;40(3):345-350.
Estimating gestational age at birth could be challenging, particularly in settings where the expertise to use conventional methods is lacking. The use of the postnatal foot length has been proposed for this purpose. The ideal tool for measuring foot length, the Vernier Digital Calliper, is not readily available in resource-poor settings.
To determine the degree of correlation between postnatal foot length measurement using a Vernier Digital Calliper and a tape measure in the estimation of gestational age among Nigerian neonates.
Neonates aged 0 to 48 hours without lower limb deformities were studied. The Gestational age was determined using the New Ballard Scoring method. The Foot length was measured as the distance between the tip of the second toe and the heel using both the Vernier Digital Calliper (FLC) and a non-elastic, flexible tape measure (FLT). The measurements were subjected to statistical comparisons.
A total of 260 newborn infants comprising 140 preterm and 120 term babies were studied. The foot length measurements using both the calliper and tape measure progressively increased with gestational age. FLT was consistently relatively higher than FLC across gestational ages. The relationship between the two tools was FLC = 3.05 + (0.9 x FLT) for preterm babies and FLC = 23.39 + (0.6 x FLT) for term babies. The Cronbach's Alpha correlation ranged from 0.775 to 0.958 across the gestational ages. The degree of agreement between the tools ranged from -2.03 to -1.34 with a mean difference of -1.68 (t = -9.67, p <0.001).
There is a high level of intra-gestational age reliability between caliper measurements and tape measurements, the latter can be suitably used as a suitable proxy for the former in the measurement of postnatal foot length in the estimation of gestational age at birth.
在缺乏使用传统方法专业知识的情况下,估计出生时的胎龄可能具有挑战性。为此,已经提出了使用产后足长的方法。理想的足部长度测量工具——游标卡尺,在资源匮乏的环境中并不容易获得。
确定使用游标卡尺和卷尺测量尼日利亚新生儿的产后足部长度,在估计胎龄方面的相关性程度。
研究了无下肢畸形的 0 至 48 小时龄新生儿。胎龄使用新 Ballard 评分法确定。使用游标卡尺(FLC)和非弹性、柔性卷尺(FLT)测量第二脚趾尖到脚跟的距离来测量足部长度。对测量值进行统计比较。
共研究了 260 名新生儿,其中包括 140 名早产儿和 120 名足月儿。使用卡尺和卷尺测量的足部长度随着胎龄的增加而逐渐增加。在整个胎龄范围内,FLT 始终高于 FLC。两种工具之间的关系为早产儿的 FLC = 3.05 +(0.9 x FLT),足月儿的 FLC = 23.39 +(0.6 x FLT)。在整个胎龄范围内,Cronbach's Alpha 相关性系数范围为 0.775 至 0.958。两种工具之间的一致性程度范围为-2.03 至-1.34,平均差异为-1.68(t = -9.67,p <0.001)。
卡尺测量和卷尺测量之间具有较高的胎内年龄可靠性,在估计出生时胎龄时,后者可以作为前者测量产后足部长度的合适替代物。