Suppr超能文献

廉价纸质化学传感器用于二价铜检测的设计与开发。

Design and Development of Inexpensive Paper-Based Chemosensors for Detection of Divalent Copper.

机构信息

Center for Advanced Materials, Qatar University, P. O Box 2713, Doha, Qatar.

Central Laboratories Unit, Qatar University, P. O Box 2713, Doha, Qatar.

出版信息

J Fluoresc. 2023 Nov;33(6):2327-2338. doi: 10.1007/s10895-023-03220-4. Epub 2023 Apr 10.

Abstract

Simple, portable, and low-cost paper-based sensors are alternative devices that have the potential to replace high-cost sensing technologies. The compatibility of the paper base biosensors for both chemical and biochemical accentuates its feasibility for application in clinical diagnosis, environmental monitoring, and food quality monitoring. High concentration of copper in blood serum and urine is associated with diseases like liver diseases, carcinomas, acute and chronic infections, rheumatoid arthritis, etc. Detection of copper concentration can give an early sign of Alzheimer disease. Apart from that genetic Wilson's disease can be detected by evaluating the concentration of copper in the urine. In view of the above advantages, a novel and the highly sensitive paper-based sensor has been designed for the selective detection of Cu ions. The fast and highly sensitive chemiresistive multi-dye system sensor can detect Cu ions selectively in as low as 2.23 ppm concentration. Least interference has been observed for counter ion in the detection of Cu. Copper chloride, nitrate, and acetate were used to validate the detection process. This assay provides a very high selectivity of Cu ion over other metal cations such as Na, Mg, Ca, etc. The easy preparation and high stability of dye solutions, easy functionalization of the paper-based sensors, high selectivity over other cations, low interference of counter anion, and significantly low detection limit of 2.23 ppm make it an effective Cu ion sensor for real-time application in near future.

摘要

简单、便携且低成本的纸质传感器是替代高成本传感技术的潜在设备。纸质生物传感器在化学和生物化学方面的兼容性突出了其在临床诊断、环境监测和食品质量监测等领域应用的可行性。血清和尿液中铜的高浓度与肝病、癌、急性和慢性感染、类风湿性关节炎等疾病有关。铜浓度的检测可以提供阿尔茨海默病的早期迹象。除此之外,通过评估尿液中铜的浓度,可以检测到遗传性威尔逊病。鉴于上述优点,我们设计了一种新型的高灵敏度基于纸的传感器,用于选择性检测 Cu 离子。快速且高灵敏度的化学电阻多染料系统传感器可以在低至 2.23ppm 的浓度下选择性地检测 Cu 离子。在检测 Cu 时,观察到反离子的干扰最小。我们使用氯化铜、硝酸盐和醋酸盐来验证检测过程。该测定法提供了 Cu 离子对其他金属阳离子(如 Na、Mg、Ca 等)的高选择性。染料溶液的制备简单、稳定性高、基于纸的传感器易于功能化、对其他阳离子具有高选择性、反阴离子干扰小且检测限低至 2.23ppm,使其成为一种有效的 Cu 离子传感器,可在不久的将来实现实时应用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/37b4/10640528/84141cbe395f/10895_2023_3220_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验