The isoelastic, noncemented total hip arthroplasty. Preliminary experience with 400 cases.

作者信息

Andrew T A, Flanagan J P, Gerundini M, Bombelli R

出版信息

Clin Orthop Relat Res. 1986 May(206):127-38.

PMID:3708965
Abstract

The first 400 patients having cementless isoelastic total hip arthroplasties with a polyacetyl femoral component stem were assessed by independent observers with a minimum review time of two years. Six percent of the patients had died at the time of review; these were mainly elderly patients with subcapital fractures. Ninety-seven percent of the surviving patients appeared for a complete clinical and radiological review. Ninety-two percent of these patients considered that they had a good result following surgery. Six patients (1.6%) developed infection, and three patients (0.8%) required revision procedures, two for femoral loosening and one for recurrent dislocation. Two (0.5%) acetabular components were loose, one of which was associated with infection. In the initial part of the series with narrow-diameter, second-generation femoral components, some had subsided and tilted into varus, but with improved instrumentation and availability of wider diameter femoral components, this problem has been overcome. In order to obtain a more secure mechanical fixation of the femoral component in the medullary canal and to increase implant-bone interface, the third-generation femoral components were used in the latter 48 cases of the series, and clinical and radiological results were excellent with corresponding reduction in the recommended period of gait support. No component had broken. Femoral fractures incurred during surgery by dislocation or impaction had all healed with routine management. These early results are encouraging, but the effectiveness of this prosthesis must be determined by longer follow-up data.

摘要

相似文献

1
The isoelastic, noncemented total hip arthroplasty. Preliminary experience with 400 cases.
Clin Orthop Relat Res. 1986 May(206):127-38.
2
[Our experience with the uncemented isoelastic total hip prosthesis].[我们使用非骨水泥型等弹性全髋关节假体的经验]
Arch Putti Chir Organi Mov. 1989;37(1):65-75.
3
[Early aseptic loosening of the CF 30 femoral stem].[CF 30股骨柄早期无菌性松动]
Acta Chir Orthop Traumatol Cech. 2007 Feb;74(1):59-64.
4
[Femoral reconstruction with endosteal bone allografts protected by a metallic mesh in reoperation of total hip prosthesis. 19 cases with an average follow-up of 83 months].[金属网保护下的骨内膜同种异体骨移植用于全髋关节置换翻修术中的股骨重建。19例患者,平均随访83个月]
Rev Chir Orthop Reparatrice Appar Mot. 1997;83(4):360-7.
5
[Butel's isoelastic hip prosthesis. A limited prospective study].[布特尔等弹性髋关节假体。一项有限的前瞻性研究]
Rev Chir Orthop Reparatrice Appar Mot. 1994;80(4):316-9.
6
[Personal experience with the Wagner revision stem in hip joint reoperations].[髋关节再次手术中使用瓦格纳翻修柄的个人经验]
Acta Chir Orthop Traumatol Cech. 2001;68(3):148-61.
7
Ceramic endoprosthesis in total hip arthroplasty.全髋关节置换术中的陶瓷假体
Clin Orthop Relat Res. 1993 Dec(297):87-94.
8
[Long-term results of the Schenker cementless femoral component].[申克无骨水泥股骨假体的长期结果]
Acta Chir Orthop Traumatol Cech. 2004;71(2):93-100.
9
[Treatment of femoral fractures on a total hip prosthesis using Charnley's "long stem" prosthesis. Apropos of 18 cases].使用查恩利“长柄”假体治疗全髋关节置换术后股骨骨折。附18例报告
Rev Chir Orthop Reparatrice Appar Mot. 1996;82(3):225-33.
10
[Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration].[联合使用ARBOND羟基磷灰石涂层在种植体骨整合方面的长期经验]
Acta Chir Orthop Traumatol Cech. 2009 Jun;76(3):172-8.

引用本文的文献

1
Bone bonding ability of a chemically and thermally treated low elastic modulus Ti alloy: gum metal.一种经过化学和热处理的低弹性模量钛合金(口香糖金属)的骨结合能力。
J Mater Sci Mater Med. 2014 Mar;25(3):635-43. doi: 10.1007/s10856-013-5101-4. Epub 2013 Nov 29.
2
A short tapered stem reduces intraoperative complications in primary total hip arthroplasty.短锥形柄可减少初次全髋关节置换术的术中并发症。
Clin Orthop Relat Res. 2012 Feb;470(2):450-61. doi: 10.1007/s11999-011-2068-7.
3
PEEK biomaterials in trauma, orthopedic, and spinal implants.
聚醚醚酮生物材料在创伤、骨科和脊柱植入物中的应用。
Biomaterials. 2007 Nov;28(32):4845-69. doi: 10.1016/j.biomaterials.2007.07.013. Epub 2007 Aug 7.
4
Peroperative fractures in uncemented total hip arthroplasty: results with a single design of stem implant.非骨水泥型全髋关节置换术中的术中骨折:采用单一设计的柄状植入物的结果
Int Orthop. 2008 Jun;32(3):307-13. doi: 10.1007/s00264-006-0318-1. Epub 2007 Jan 20.
5
Revision arthroplasty with an isoelastic uncemented femoral stem.采用等弹性非骨水泥型股骨柄的翻修关节成形术。
Int Orthop. 1995;19(5):298-303. doi: 10.1007/BF00181114.
6
[Surgical hip joint replacement with a cement-free fixation technic--indications, technic and results].[采用无骨水泥固定技术的髋关节置换术——适应证、技术及结果]
Langenbecks Arch Chir. 1987;372:465-9. doi: 10.1007/BF01297864.
7
Ring uncemented plastic on metal hip replacements--results from an independent unit.金属髋关节置换术中未使用骨水泥的塑料环——独立单元的结果
J R Soc Med. 1989 Mar;82(3):142-4. doi: 10.1177/014107688908200309.
8
Histological features of the interface membrane of failed isoelastic cementless prostheses.失效等弹性非骨水泥假体界面膜的组织学特征。
Int Orthop. 1990;14(4):399-403. doi: 10.1007/BF00182653.