We evaluated the feasibility of a juxta-articular-type volar distal radius plate for the surgical treatment of marginal distal radius fractures.
Twenty marginal distal radius fractures, defined by the location of the fracture line within 10 mm of the joint line of the lunate fossa, were retrospectively reviewed between July 2020 and July 2022. The fractures were fixed using a juxta-articular-type volar plate (ARIX Wrist System). The characteristics of the implant and surgical technique, radiologic, and clinical outcomes, and related complications were evaluated.
Bony union was achieved in all patients within six months. Acceptable radiological alignment was achieved with no significant differences between the fractured and the normal sides. The clinical outcomes were favorable, with satisfactory functional outcomes. There was one case of post-traumatic arthritis and two cases of carpal tunnel syndrome. No implant-related complications including flexor tendon problems were observed.
The juxta-articular distal radius plate of the Arix Wrist system is feasible for treating marginal distal radius fractures and achieves favorable clinical outcomes without implant-related complications in East Asian patients.
我们评估了一种关节旁型桡骨远端掌侧钢板用于手术治疗桡骨远端边缘骨折的可行性。
回顾性分析2020年7月至2022年7月期间收治的20例桡骨远端边缘骨折患者,骨折线位于月骨窝关节线10毫米范围内。采用关节旁型掌侧钢板(ARIX腕关节系统)固定骨折。评估植入物的特点、手术技术、影像学及临床结果以及相关并发症。
所有患者均在六个月内实现骨愈合。骨折侧与正常侧在放射学对线方面达到可接受水平,无显著差异。临床结果良好,功能结局令人满意。有1例创伤后关节炎和2例腕管综合征。未观察到包括屈肌腱问题在内的与植入物相关的并发症。
Arix腕关节系统的关节旁桡骨远端钢板对于治疗桡骨远端边缘骨折是可行的,并且在东亚患者中取得了良好的临床结果,且无植入物相关并发症。