Suppr超能文献

分析鉴定并区分苏式-和赤式-4-氟乙基苯丙胺。

Analytical characterization and differentiation between threo- and erythro-4-fluoroethylphenidate.

机构信息

Tokyo Metropolitan Institute of Public Health, 24-1 Hyakunincho 3-chome, Shinjuku-ku, Tokyo, 169-0073, Japan.

Tokyo Food Sanitation Association Food Research Laboratory, 1-19-10 Tokumaru, Itabashi-ku, Tokyo, 175-0083, Japan.

出版信息

Forensic Toxicol. 2023 Jul;41(2):272-286. doi: 10.1007/s11419-023-00664-y. Epub 2023 Apr 25.

Abstract

PURPOSE

Methylphenidate analogs appeared on the drug market during the last years. Its analogs contain two chiral centers and, thus, have potential varying configurations (i.e., threo and erythro forms). This study presents the analytical characterization of 4-fluoroethylphenidate (4-FEP) and its differentiation between threo- and erythro-4-FEP.

METHODS

Analysis of the samples included high-performance liquid chromatography (HPLC), gas chromatography-electron ionization-mass spectrometry (GC-EI-MS), high-resolution mass spectrometry (HRMS) analyses, nuclear magnetic resonance (NMR) spectroscopy and X-ray crystal structure analysis.

RESULTS

NMR spectroscopic investigations confirmed the differences between threo- and erythro-4-FEP, and demonstrated that both isomers could be separated using HPLC and GC methods. Two samples obtained from one vendor in 2019 consisted of threo-4-FEP, whereas the other two samples obtained from a different vendor in 2020 consisted of a mixture of threo- and erythro-4-FEP.

CONCLUSIONS

Several analytical approaches including HPLC, GC-EI-MS, HRMS analyses, NMR spectroscopy and X-ray crystal structure analysis enabled the unambiguous identification of threo- and erythro-4-FEP. The analytical data presented in this article will be useful for identifying threo- and erythro-4-FEP included in illicit products.

摘要

目的

近年来,哌醋甲酯类似物出现在毒品市场上。其类似物含有两个手性中心,因此具有潜在的不同构型(即苏式和赤式)。本研究对 4-氟乙基苯丙胺(4-FEP)进行了分析鉴定,并对其苏式和赤式异构体进行了区分。

方法

样品分析包括高效液相色谱(HPLC)、气相色谱-电子电离-质谱(GC-EI-MS)、高分辨率质谱(HRMS)分析、核磁共振(NMR)波谱和 X 射线晶体结构分析。

结果

NMR 波谱研究证实了苏式和赤式 4-FEP 之间的差异,并表明两种异构体均可通过 HPLC 和 GC 方法分离。2019 年从一个供应商获得的两个样品均为苏式 4-FEP,而 2020 年从另一个供应商获得的另外两个样品则为苏式和赤式 4-FEP 的混合物。

结论

包括 HPLC、GC-EI-MS、HRMS 分析、NMR 波谱和 X 射线晶体结构分析在内的几种分析方法可明确鉴定苏式和赤式 4-FEP。本文提供的分析数据将有助于鉴定包含在非法产品中的苏式和赤式 4-FEP。