Abstract

The critical flicker fusion frequency (cFFF) refers to the frequency at which a regularly recurring change of light stimuli is perceived as steady. The cFFF threshold is often assessed in clinics to evaluate the temporal characteristics of the visual system, making it a common test for eye diseases. Additionally, it serves as a helpful diagnostic tool for various neurological and internal diseases. In the field of diving/hyperbaric medicine, cFFF has been utilized to determine alertness and cognitive functions. Changes in the cFFF threshold have been linked to the influence of increased respiratory gas partial pressures, although there exist inconsistent results regarding this effect. Moreover, the use of flicker devices has produced mixed outcomes in previous studies. This narrative review aims to explore confounding factors that may affect the accuracy of cFFF threshold measurements, particularly in open-field studies. We identify five broad categories of such factors, including (1) participant characteristics, (2) optical factors, (3) smoking/drug use, (4) environmental aspects, and (5) breathing gases and partial pressures. We also discuss the application of cFFF measurements in the field of diving and hyperbaric medicine. In addition, we provide recommendations for interpreting changes in the cFFF threshold and how they are reported in research studies.

摘要

临界闪烁融合频率(cFFF)是指当光刺激以规则的频率重复出现时,人眼感知到的稳定频率。在临床中,通常通过评估 cFFF 阈值来评估视觉系统的时间特性,因此它是一种常见的眼部疾病检测方法。此外,它还可作为各种神经和内科疾病的有用诊断工具。在潜水/高压医学领域,cFFF 已被用于确定警觉性和认知功能。尽管关于这种影响的结果并不一致,但 cFFF 阈值的变化与呼吸气体分压增加的影响有关。此外,在之前的研究中,闪烁设备的使用产生了不同的结果。本叙述性综述旨在探讨可能影响 cFFF 阈值测量准确性的混杂因素,特别是在开放场研究中。我们确定了五类这样的因素,包括(1)参与者特征,(2)光学因素,(3)吸烟/药物使用,(4)环境方面,以及(5)呼吸气体和分压。我们还讨论了 cFFF 测量在潜水和高压医学领域的应用。此外,我们提供了关于解释 cFFF 阈值变化的建议,并介绍了如何在研究报告中报告这些变化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3abd/10141404/af79a98856b1/medicina-59-00800-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验