Suppr超能文献

[Zweymueller-Endler全髋关节假体的非骨水泥植入。2年的临床、放射学和闪烁扫描随访]

[Cementless implantation of Zweymueller-Endler total endoprosthesis of the hip. Clinical, radiologic and scintigraphic follow-up of 2 years].

作者信息

Schicha H, Perner K, Voth E, Reith H G, Willert H G, Emrich D

出版信息

Nuklearmedizin. 1986 Apr;25(2):55-60.

PMID:3714513
Abstract

Sixty-four patients with cementless Zweymueller-Endler total endoprostheses of the hip underwent follow-up postoperatively for 2 years. In 3 patients loosening or infection occurred. In 61 patients no complications were observed. However, in 74% of these patients increasing activity uptake at the tip of the shaft was found by scintigraphy. This was associated with hypertrophy of the corticalis and/or with a marrow cavity reaction, observed radiologically. The results show that scintigraphic evaluation of cementlessly implanted Zweymueller-Endler endoprostheses of the hip must be interpreted differently compared to isoelastic or to cemented prostheses.

摘要

64例接受了Zweymueller-Endler非骨水泥型全髋关节置换术的患者术后接受了2年的随访。3例患者出现假体松动或感染。61例患者未观察到并发症。然而,在这些患者中的74%,通过闪烁扫描发现在股骨干末端有活动性摄取增加。这与放射学上观察到的骨皮质肥厚和/或骨髓腔反应有关。结果表明,与等弹性假体或骨水泥型假体相比,对非骨水泥植入的Zweymueller-Endler髋关节假体进行闪烁扫描评估时,其结果的解读有所不同。

文献AI研究员