Köster G, Munz D L, Köhler H P
Abteilung Orthopädie, Georg-August-Universität, Göttingen, Germany.
Arch Orthop Trauma Surg. 1993;112(5):247-54. doi: 10.1007/BF00451886.
Combined contrast and radionuclide arthrography was performed in 71 cemented, non-cemented and hybrid hip arthroplasties for diagnosis of component loosening. In 31 cases, either one or two prosthesis components were clearly loose upon clinical and radiological diagnosis, with subsequent intraoperative confirmation. The other 40 cases had doubtful component loosening, with discrepancy between clinical and radiological findings, and were investigated for clarification. Contrast and radionuclide arthrograms were compared with sequential plain radiographs and their ability to indicate component loosening was evaluated. The combined contrast and radionuclide arthrograms proved in 90.9% of the cases whether a loose component existed as confirmed by intraoperative findings. They had a high sensitivity, specificity and predictive accuracy for both the acetabular and the femoral component. Sensitivity and predictive accuracy were remarkably precise in comparison to those of plain radiographs on the acetabular side. In nearly all patients with contradictory clinical and radiological findings, conclusive diagnosis was possible on the basis of the contrast and radionuclide arthrograms. Coinciding positive results in both contrast and radionuclide arthrograms were verified in each operated case. The combination of contrast and radionuclide arthrography is an useful method to diagnose doubtful loosening of hip arthroplasty components, especially in addition to routine sequential plain radiographs.
对71例骨水泥型、非骨水泥型和混合型髋关节置换术进行了联合对比造影和放射性核素关节造影,以诊断假体松动。31例经临床和放射学诊断,一个或两个假体组件明显松动,随后术中得到证实。另外40例假体松动情况可疑,临床和放射学检查结果存在差异,因此进行调查以明确情况。将对比造影和放射性核素关节造影与连续的平片进行比较,并评估它们显示假体松动的能力。联合对比造影和放射性核素关节造影在90.9%的病例中证实了术中发现的假体组件是否松动。它们对髋臼和股骨组件都具有较高的敏感性、特异性和预测准确性。与髋臼侧平片相比,敏感性和预测准确性非常精确。在几乎所有临床和放射学检查结果相互矛盾的患者中,基于对比造影和放射性核素关节造影都可以做出确定性诊断。在每个手术病例中,对比造影和放射性核素关节造影的阳性结果都相互吻合。联合对比造影和放射性核素关节造影是诊断髋关节置换术组件可疑松动的一种有用方法,特别是在常规连续平片之外。