Krishnamurthy Vani, Shivamurthy Archana, Kumar Pradeep V
Department of Pathology, JSS Medical College, Mysore, Karnataka, India.
Department of Hematology, Anand Diagnostic Laboratory, Bengaluru, Karnataka, India.
Asian J Transfus Sci. 2023 Jan-Jun;17(1):131-132. doi: 10.4103/ajts.ajts_65_21. Epub 2022 Sep 28.
Among the blood counts, platelet count is most often reported with inconsistency. Many of the analyzers work on electrical impedance principle for red blood cell (RBC) and platelet counting. However, with this technology, factors such as fragmented RBCs, microcytes, cytoplasmic fragments of leukemic cells, lipid particles, fungal yeast forms, and bacteria are known to interfere with platelet count and give spuriously elevated platelet counts. A 72-year-old male was admitted for the treatment of dengue infection who had serial platelet count monitoring. He had an initial platelet count of 48,000/cumm which suddenly improved to 2.6 lakhs within 6 h without any platelet transfusion. Peripheral smear however did not correlate with the machine-derived count. Repeat test after 6 h yielded a result of 56,000/cumm which correlated well with the peripheral smear. This falsely elevated count was due to the presence of lipid particles as the sample was drawn in the postprandial state.
在血细胞计数中,血小板计数的报告往往最不一致。许多分析仪采用电阻抗原理进行红细胞(RBC)和血小板计数。然而,使用这种技术时,已知诸如破碎红细胞、小红细胞、白血病细胞质碎片、脂质颗粒、真菌酵母形态和细菌等因素会干扰血小板计数,并导致血小板计数假性升高。一名72岁男性因登革热感染入院接受治疗,期间进行了连续的血小板计数监测。他最初的血小板计数为48,000/立方毫米,在未进行任何血小板输注的情况下,6小时内突然升至26万/立方毫米。然而,外周血涂片结果与仪器检测计数不相符。6小时后复查,结果为56,000/立方毫米,与外周血涂片结果良好相符。这种计数假性升高是由于样本是在餐后状态采集的,存在脂质颗粒所致。