Suppr超能文献

流式细胞术解析急性髓系白血病中白血病细胞胞质碎片导致的血小板计数干扰。

Resolution of platelet count interference due to cytoplasmic fragments of leukaemic cells by flow cytometry in acute myeloid leukaemia.

机构信息

Division of Haematology, Department of Clinical Pathology, Tuen Mun Hospital, Tuen Mun, Hong Kong.

出版信息

Int J Lab Hematol. 2022 Dec;44(6):983-985. doi: 10.1111/ijlh.13859. Epub 2022 May 3.

Abstract

BACKGROUND

Platelet count interference could lead to problems in clinical decisions especially in the cases of thrombocytopenia. Here we report a case of platelet count interference in Beckman Coulter DxH800 haematology analyser due to cytoplasmic fragments of leukaemic cells in acute myeloid leukaemia. A 19-year-old female patient presented to the emergency department with bruises and anaemic symptoms. A machine platelet count (by impedance method) was 40 × 10 /L. There was a flag on platelet count interference by debris. Peripheral blood smear showed some bluish cytoplasmic fragments are seen mimicking platelets.

METHOD

Immunological platelet counting by flow cytometry using fluorochrome-labeled antibodies against platelet markers CD41 and CD61 was attempted by adopting and modifying from the ICSH reference method for platelet counting. Events with low forward scatter and positive CD41 and/or CD61 expression were identified as platelets, and events with high forward scatter and negative CD41 and CD61 expression were identified as red cells.

RESULTS

The platelet count was derived from the formula: Platelet count = RBC count (Haematology analyser) × PLT event (flow cytometry)/RBC events (flow cytometry). The immunological platelet count was determined to be 2 × 10 /L, which is much lower than the original machine count and platelet transfusion was warranted.

摘要

背景

血小板计数干扰可能导致临床决策出现问题,尤其是在血小板减少症的情况下。我们在此报告一例由于急性髓细胞白血病中的白血病细胞胞质碎片导致贝克曼库尔特 DxH800 血液分析仪血小板计数干扰的病例。一名 19 岁女性因瘀斑和贫血症状就诊于急诊部。仪器血小板计数(阻抗法)为 40×10 /L。血小板计数干扰存在碎片的标志。外周血涂片显示一些蓝色胞质碎片,类似血小板。

方法

采用并修改国际血液学标准化委员会(ICSH)血小板计数参考方法,尝试通过流式细胞术用荧光标记的血小板标志物 CD41 和 CD61 抗体进行免疫血小板计数。用低前向散射和阳性 CD41 和/或 CD61 表达鉴定为血小板,用高前向散射和阴性 CD41 和 CD61 表达鉴定为红细胞。

结果

血小板计数由公式得出:血小板计数=血液分析仪 RBC 计数×(流式细胞术的 PLT 事件/RBC 事件)。免疫血小板计数确定为 2×10 /L,远低于原始仪器计数,需要进行血小板输注。