Suppr超能文献

在短时间内,精神病患者和社区志愿者瞳孔对光反射的可重复性。

Reproducibility of the pupillary light reflex over short intervals in psychiatric patients and community volunteers.

机构信息

Department of Psychiatry and Health Behavior, Medical College of Georgia, Augusta University, Augusta, Georgia, USA.

出版信息

Clin Physiol Funct Imaging. 2023 Sep;43(5):365-372. doi: 10.1111/cpf.12834. Epub 2023 May 24.

Abstract

The pupillary light reflex (PLR) is a method for measuring dynamic responses within the autonomic nervous system, and would have potential value as a point-of-care test in a psychiatry clinic if reproducible results could be obtained in a short period of time. We collected PLR from adult community volunteers and depressed outpatients with the purpose of demonstrating (1) that valid data could be obtained >90% of the time from both the community volunteers and the patients, and (2) that reproducible results could be obtained with repeated measurement over short periods of time. Valid data were captured for 90.3% of 76 participants, allowing for two attempts of the PLR per participant. Success rates were similar for depressed patients and community volunteers. Eighteen of these 76 participants provided repeated paired measurements after 5 and 10 min of dark adaptation, producing high correlations for maximum constriction velocity (MCV) between assay 1 and 2 (Pearson's r = 0.71, p < 0.001), but there was a significant 8% increase in velocity for MCV between assay 1 and 2 (∆ = 0.34 ± 0.59 mm/s, p < 0.05). In contrast, PLR measurements were stable when tested in a separate cohort of 21 additional participants at 10 and 15 min of dark adaptation with an MCV Pearson's correlation of r = 0.84, p < 0.001, with a nonsignificant 1% difference between the two time points. These findings indicate an acceptable rate of collecting valid and reproducible PLR data when contrasting two measurements of PLR after 10 or 15 min of dark adaptation in depressed and suicidal patients.

摘要

瞳孔对光反射(PLR)是测量自主神经系统动态反应的一种方法,如果能够在短时间内获得可重复的结果,它将有可能成为精神病诊所的即时检测方法。我们从成年社区志愿者和抑郁门诊患者中收集 PLR,旨在证明:(1)从社区志愿者和患者中,有 90%以上的时间可以获得有效数据;(2)在短时间内重复测量可以获得可重复的结果。在 76 名参与者中,有 90.3%的参与者成功采集到有效数据,允许每位参与者进行两次 PLR 尝试。抑郁患者和社区志愿者的成功率相似。其中 18 名参与者在黑暗适应 5 和 10 分钟后重复进行配对测量,两次测定之间最大收缩速度(MCV)的相关性较高(Pearson r=0.71,p<0.001),但两次测定之间 MCV 的速度显著增加了 8%(∆=0.34±0.59 mm/s,p<0.05)。相比之下,在另一组 21 名参与者中,在黑暗适应 10 和 15 分钟时进行 PLR 测试,MCV 的 Pearson 相关性为 r=0.84,p<0.001,两次测定之间没有显著差异(1%)。这些发现表明,在抑郁和自杀患者中,在黑暗适应 10 或 15 分钟后对比两次 PLR 测量时,收集有效和可重复的 PLR 数据的速率是可以接受的。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验