Observations on the effect of movement on bone ingrowth into porous-surfaced implants.

作者信息

Pilliar R M, Lee J M, Maniatopoulos C

出版信息

Clin Orthop Relat Res. 1986 Jul(208):108-13.

PMID:3720113
Abstract

Although porous-surfaced orthopedic implants have been designed for fixation by bone ingrowth, there is clinical evidence that this does not always occur. Initial implant movement relative to host bone can result in attachment by a nonmineralized fibrous connective tissue layer. The ranges of movement that result in either bone or fibrous connective tissue fixation are observed in dogs in two independent studies. Experimentally, bone ingrowth can occur in the presence of some movement, albeit very small (up to 28 mu), while excess movement (150 mu or more) can result in attachment by mature connective tissue ingrowth.

摘要

相似文献

1
Observations on the effect of movement on bone ingrowth into porous-surfaced implants.
Clin Orthop Relat Res. 1986 Jul(208):108-13.
2
Threaded versus porous-surfaced designs for implant stabilization in bone-endodontic implant model.用于骨内牙髓种植体模型中种植体稳定的螺纹设计与多孔表面设计
J Biomed Mater Res. 1986 Nov-Dec;20(9):1309-33. doi: 10.1002/jbm.820200907.
3
Study of soft tissue ingrowth into canine porous coated femoral implants designed for osteosarcomas management.
J Biomed Mater Res. 1990 Jul;24(7):959-71. doi: 10.1002/jbm.820240712.
4
Radiographic and morphologic studies of load-bearing porous-surfaced structured implants.
Clin Orthop Relat Res. 1981 May(156):249-57.
5
Enhanced bone ingrowth and fixation strength with hydroxyapatite-coated porous implants.羟基磷灰石涂层多孔植入物增强骨长入和固定强度。
Semin Arthroplasty. 1991 Oct;2(4):268-79.
6
The effect of porous surface configuration on the tensile strength of fixation of implants by bone ingrowth.多孔表面结构对植入物通过骨长入实现固定的拉伸强度的影响。
Clin Orthop Relat Res. 1980 Jun(149):291-8.
7
"Biologic width"and crestal bone remodeling with sintered porous-surfaced dental implants: a study in dogs.
Int J Oral Maxillofac Implants. 2008 May-Jun;23(3):544-50.
8
Threaded versus porous-surfaced implants as anchorage units for orthodontic treatment: three-dimensional finite element analysis of peri-implant bone tissue stresses.螺纹式与多孔表面种植体作为正畸治疗的支抗单位:种植体周围骨组织应力的三维有限元分析
Int J Oral Maxillofac Implants. 2006 Nov-Dec;21(6):879-89.
9
Adjuvant therapies of bone graft around non-cemented experimental orthopedic implants stereological methods and experiments in dogs.非骨水泥型实验性骨科植入物周围骨移植的辅助治疗:体视学方法及犬实验
Acta Orthop Suppl. 2008 Aug;79(330):1-43.
10
The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris.光滑种植体表面对种植体周围纤维化及聚乙烯磨损颗粒迁移的易感性。
Clin Orthop Relat Res. 1995 Feb(311):21-39.

引用本文的文献

1
The Influence of Reaming Velocity During Preparation of the Femoral Canal-An In Vitro Analysis of Two Straight Femoral Revision Stems with a Fluted Tapered Design.股骨髓腔准备过程中扩髓速度的影响——两种带槽锥形设计的直柄股骨翻修假体的体外分析
Bioengineering (Basel). 2025 Sep 16;12(9):984. doi: 10.3390/bioengineering12090984.
2
Primary stability of short stem prostheses for the shoulder-a biomechanical comparative study of two short stem designs.肩部短柄假体的初始稳定性——两种短柄设计的生物力学对比研究
Arch Orthop Trauma Surg. 2025 Aug 20;145(1):416. doi: 10.1007/s00402-025-06041-1.
3
Biomechanical evaluation of bispherical augments in acetabular defect reconstruction and comparative study of different fixation methods.
双球形增强物在髋臼缺损重建中的生物力学评估及不同固定方法的比较研究
BMC Musculoskelet Disord. 2025 Aug 7;26(1):758. doi: 10.1186/s12891-025-09006-y.
4
Towards an Automated Computational Workflow to Assess Primary Stability in Total Hip Arthroplasty.迈向用于评估全髋关节置换术中初始稳定性的自动化计算工作流程。
Bioengineering (Basel). 2025 Jun 30;12(7):723. doi: 10.3390/bioengineering12070723.
5
Baseplate coverage in reverse total shoulder arthroplasty: a systematic review.反向全肩关节置换术中的基板覆盖范围:一项系统评价
JSES Rev Rep Tech. 2025 Mar 29;5(3):460-468. doi: 10.1016/j.xrrt.2025.02.010. eCollection 2025 Aug.
6
A Modified Wagner Stem Design Increases the Primary Stability in Cementless Revision Hip Arthroplasty.一种改良型瓦格纳柄设计可提高非骨水泥型髋关节翻修术中的初始稳定性。
Arthroplast Today. 2025 Feb 3;32:101622. doi: 10.1016/j.artd.2025.101622. eCollection 2025 Apr.
7
A high offset stem design does not increase stem migration under full weight bearing in cementless total hip arthroplasty: a model-based RSA study.在非骨水泥型全髋关节置换术中,高偏移柄设计不会增加全负重状态下柄的移位:一项基于模型的RSA研究。
Arthroplasty. 2025 Feb 4;7(1):7. doi: 10.1186/s42836-024-00290-y.
8
Short humeral stem in total shoulder arthroplasty does not jeopardize primary implant stability.全肩关节置换术中使用短肱骨干假体不会影响初次植入的稳定性。
JSES Int. 2024 Oct 3;9(1):212-218. doi: 10.1016/j.jseint.2024.09.021. eCollection 2025 Jan.
9
Improved primary stability and load transfer of a customized osseointegrated transfemoral prosthesis compared to a commercial one.与商用产品相比,定制的骨整合型经股骨假肢的初始稳定性和负荷传递得到改善。
J Orthop Surg Res. 2025 Jan 27;20(1):102. doi: 10.1186/s13018-025-05476-x.
10
Reverse Shoulder Arthroplasty Baseplate Stability Is Affected by Bone Density and the Type and Amount of Augmentation.反肩关节置换术的基板稳定性受骨密度以及增强类型和增强量的影响。
Bioengineering (Basel). 2025 Jan 8;12(1):42. doi: 10.3390/bioengineering12010042.