Comparison of Loss of Torque between Gold and Titanium Alloy Abutment Screws in Dental Implants without Any Cyclic Loads.

机构信息

Department of Prosthodontics, Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India, Phone: +91 9080096491, e-mail:

Department of Prosthodontics and Implantology, Sai Poly Clinic, Chennai, Tamil Nadu, India.

出版信息

J Contemp Dent Pract. 2022 Aug 1;23(8):801-806. doi: 10.5005/jp-journals-10024-3388.

Abstract

AIM

To find and compare the amount of screw loosening in gold and titanium alloy abutment screws without any cyclic load, this study was performed.

MATERIALS AND METHODS

A total of 20 implant fixture screw samples with 10 gold abutment screws from Osstem and 10 titanium alloy abutment screws from Genesis. Implant fixtures were placed into the acrylic resin using a surveyor to maintain the same path of insertion. Using a hex driver and calibrated torque wrench, initial torque was given according to the manufacturer's recommendation. One vertical and other horizontal lines were drawn over the head of the hex driver and resin block. Acrylic block position was standardized using a putty index in a fixed table and using a tripod stand a digital single-lens reflex camera (DSLR) camera was positioned with its horizontal arm facing the floor, as well as perpendicular to the acrylic box. Photographs were taken immediately after the application of the initial torque given as per the manufacturer's recommendation and 10 minutes after the initial torque. Re-torque of 30 and 35 N cm was given to gold and titanium alloy abutment screws respectively. Photographs were taken again in that same position immediately after re-torquing and 3 hours after re-torquing. The photographs were uploaded into the Fiji-win64 analysis software and the angulations were measured in each photograph.

RESULTS

Both the gold and titanium alloy abutment screws exhibited screw loosening after initial torquing. There was a significant difference in the amount of screw loosening between gold and titanium alloy abutment screws after initial torquing and no change in the abutment screw position after three hours of re-torquing.

CONCLUSION

Re-torquing of both gold and titanium alloy abutment screws after 10 minutes of initial torquing should be performed routinely for retaining the preload and minimizing the screw loosening even before loading the implant fixture.

CLINICAL SIGNIFICANCE

Gold abutment screws may have the ability to retain the preload better than the titanium alloy abutment screws after initial torquing, re-torquing may be necessary after 10 minutes to reduce the settling effect in a routine clinical procedure.

摘要

目的

在无循环载荷的情况下,寻找并比较金和钛合金基台螺钉的松动量。

材料和方法

共收集 20 个种植体螺丝样本,其中 10 个为奥齿泰(Osstem)的金基台螺丝,10 个为创英(Genesis)的钛合金基台螺丝。种植体螺丝通过测深仪被固定于丙烯酸树脂中,以保持相同的插入路径。使用六角驱动和校准扭矩扳手,根据制造商的建议初始扭矩。在六角驱动器和树脂块的头部绘制一条垂直线和另一条水平线。使用腻子指数将丙烯酸块的位置标准化在固定表中,使用三脚架立数字单镜头反光相机(DSLR)使其水平臂朝向地面,以及垂直于丙烯酸盒。立即在根据制造商的建议施加初始扭矩后拍摄照片,并在初始扭矩后 10 分钟拍摄照片。分别给金和钛合金基台螺钉施加 30 和 35 N cm 的再扭矩。在同一位置立即再次拍摄照片,并在再扭矩后 3 小时再次拍摄照片。将照片上传到 Fiji-win64 分析软件中,并测量每个照片中的角度。

结果

金和钛合金基台螺钉在初始扭矩后都出现了螺钉松动。初始扭矩后,金和钛合金基台螺钉的螺钉松动量有显著差异,再扭矩后 3 小时基台螺钉位置无变化。

结论

即使在加载种植体之前,在初始扭矩 10 分钟后,应常规对金和钛合金基台螺钉进行再扭矩,以保持预载并最大程度减少螺钉松动。

临床意义

在初始扭矩后,金基台螺钉可能比钛合金基台螺钉更能保持预载,在常规临床操作中,10 分钟后可能需要再扭矩以减少沉降效应。