Suppr超能文献

游离皮瓣移植实验中吻合技术的评估

Evaluation of anastomotic techniques in the experimental transfer of free skin flaps.

作者信息

Parsa F D, Spira M

出版信息

Plast Reconstr Surg. 1979 May;63(5):696-9. doi: 10.1097/00006534-197905000-00014.

Abstract

Vascularized groin flaps were transferred to the contralateral side by various microvascular anastomotic techniques. There was no statistical difference between the results of end-to-end and end-to-side anastomoses, when the same sized vessels were compared. However, significant differences existed when vessels smaller than 0.5 mm in diameter were anastomosed.

摘要

采用多种微血管吻合技术将带血管蒂腹股沟皮瓣转移至对侧。当比较相同口径血管时,端端吻合和端侧吻合的结果无统计学差异。然而,当吻合直径小于0.5毫米的血管时,存在显著差异。