Department of Physical Therapy and Rehabilitation Science, University of Iowa, Iowa City, IA, USA.
Department of Orthopaedics & Rehabilitation, University of Iowa, Iowa City, IA, USA.
Phys Ther Sport. 2023 Jul;62:10-16. doi: 10.1016/j.ptsp.2023.05.006. Epub 2023 Jun 1.
To determine the inter-rater reliability and criterion validity of two-dimensional (2D) measures of ankle function in the sagittal plane for participants with Achilles tendinopathy (AT).
Cohort study.
University Laboratory, Participants, Adults with AT (N = 18, Women: 72.2%, Age = 43.4 ± 15.8 years, BMI = 28.7 ± 8.9 kg/m) MAIN OUTCOME MEASURES: Reliability and validity were determined with intra-class correlation coefficients (ICC), standard error of the measurement (SEM), minimal detectable change (MDC), and Bland-Altman plots for ankle dorsiflexion and positive work during heel raises.
Inter-rater reliability between three raters for all 2D motion analysis tasks was good to excellent (ICC = 0.88 to 0.99). Criterion validity between 2D and 3D motion analyses for all tasks was good to excellent (ICC = 0.76 to 0.98). 2D motion analysis overestimated ankle dorsiflexion motion by 1.0-1.7° (3% of mean sample value) and positive ankle joint work by 76.8 J (9% of mean) compared to 3D motion analysis.
Although 2D and 3D measures are not interchangeable, the good to excellent reliability and validity of 2D measures in the sagittal plane support the use of video analysis to quantify ankle function for individuals with foot and ankle pain.
确定跟腱病(AT)患者矢状面二维(2D)踝关节功能测量的组内信度和标准效度。
队列研究。
大学实验室,参与者,跟腱病患者(N=18,女性:72.2%,年龄=43.4±15.8 岁,BMI=28.7±8.9kg/m)。
使用组内相关系数(ICC)、测量标准误差(SEM)、最小可检测变化(MDC)和 Bland-Altman 图评估踝关节背屈和跟腱抬高时正功的可靠性和有效性。
三位评估者对所有 2D 运动分析任务的组内信度均为良好至优秀(ICC=0.88 至 0.99)。所有任务的 2D 与 3D 运动分析之间的标准效度均为良好至优秀(ICC=0.76 至 0.98)。与 3D 运动分析相比,2D 运动分析高估了踝关节背屈运动 1.0-1.7°(平均值的 3%)和正踝关节功 76.8J(平均值的 9%)。
尽管 2D 和 3D 测量不可互换,但 2D 矢状面测量具有良好至优秀的可靠性和有效性,支持使用视频分析来量化足部和踝关节疼痛患者的踝关节功能。