Suppr超能文献

现代舞者功能性踝关节运动测量的比较

Comparison of Functional Ankle Motion Measures in Modern Dancers.

作者信息

Dickson Danelle, Hollman-Gage Kendra, Ojofeitimi Sheyi, Bronner Shaw

机构信息

Physical Therapy Sports and Assessment Center, Washington, DC, USA.

Athletico, Ltd., Chicago, Illinois, USA.

出版信息

J Dance Med Sci. 2012 Sep;16(3):116-25.

Abstract

Ankle injuries are the most common lower extremity injury in dance and sports, often resulting in limitation of dorsiflexion or plantar flexion. Accurate assessment of any limitation in range of motion is an important factor in implementing effective preventative and rehabilitative regimens. Ankle range of motion has traditionally been quantified with goniometers. However, standard goniometry may not be an adequate method of assessing plantar flexion range of motion in dancers. An alternative technique using inclinometers to quantify ankle plantar flexion has been reported, but reliability and inter-instrument correlations for this method are limited. The dorsiflexion lunge distance method has been used to assess ankle dorsiflexion. Although shown to be reliable, this method has not been objectively correlated. The purpose of this study was to determine the most clinically appropriate tool for assessing functional ankle dorsiflexion and plantar flexion in dancers. The aims were to: 1. determine reliability of the weightbearing ankle dorsiflexion lunge method using inclinometer, goniometer, and distance; 2. assess the reliability of inclinometer and goniometer measurements of non-weightbearing active plantar flexion; 3. conduct inter-method and experienced versus novice rater correlations; and 4. determine if a relationship exists between dorsiflexion distance (cm) and dorsiflexion inclinometer angle (degrees) measurements. Twenty-six modern dancers (age: 20.2 ± 1.8 years) participated in the study. Four raters measured weightbearing dorsiflexion in a lunge position using a goniometer, two inclinometer placements, and a distance measurement. They also measured active ankle plantar flexion using an inclinometer placed on the anterior talonavicular joint and a goniometer placed at the lateral ankle. Intra- and inter-rater reliability and inter-method correlations were calculated with Intraclass Correlation Coefficients (ICC) and standard error of measurement (SEM). The relationship of dorsiflexion distance to angle was determined using grouped linear regression (p < 0.05). Dorsiflexion and plantar flexion intra- and inter-rater ICCs for inclinometer, goniometer, and distance ranged from 0.84 to 0.99. The SEM for angular measures ranged from 1° to 3°, and linear measures from 0.3 cm to 0.9 cm. Inter-method correlations ranged from 0.55 to 0.89. There were no differences between inclinometer and goniometer measurement dorsiflexion means. However, inclinometer plantar flexion values were greater than goniometric values (p < 0.001). Experienced raters recorded greater goniometric values compared to novice raters (p < 0.01). There was no consistent linear relationship between dorsiflexion lunge distance measure and inclinometer degrees. It is concluded that functional ankle DF in modern dancers is best quantified using an inclinometer (posterior placement) in the weightbearing lunge position. Non-weightbearing active ankle PF in modern dancers is best quantified with inclinometer placement on the dorsum of the foot. The distance method cannot be compared directly to angular measurement, is subject-specific, and cannot be used as a normative measure to compare DF range between subjects, populations, or age groups.

摘要

踝关节损伤是舞蹈和体育运动中最常见的下肢损伤,常导致背屈或跖屈受限。准确评估运动范围的任何限制是实施有效预防和康复方案的重要因素。传统上,踝关节活动范围是用角度计来量化的。然而,标准角度测量法可能不是评估舞者跖屈活动范围的合适方法。已有报道一种使用倾角计量化踝关节跖屈的替代技术,但该方法的可靠性和仪器间相关性有限。背屈弓步距离法已用于评估踝关节背屈。尽管该方法被证明是可靠的,但尚未进行客观关联。本研究的目的是确定评估舞者功能性踝关节背屈和跖屈的最适合临床的工具。目标是:1. 确定使用倾角计、角度计和距离测量的负重踝关节背屈弓步法的可靠性;2. 评估非负重主动跖屈的倾角计和角度计测量的可靠性;3. 进行方法间以及经验丰富与新手评估者的相关性分析;4. 确定背屈距离(厘米)和背屈倾角计角度(度)测量之间是否存在关系。26名现代舞者(年龄:20.2±1.8岁)参与了该研究。四名评估者使用角度计、两种倾角计放置方式和距离测量法在弓步姿势下测量负重背屈。他们还使用放置在前距舟关节的倾角计和放置在踝关节外侧的角度计测量主动踝关节跖屈。使用组内相关系数(ICC)和测量标准误差(SEM)计算评估者内和评估者间的可靠性以及方法间相关性。使用分组线性回归确定背屈距离与角度的关系(p<0.05)。倾角计、角度计和距离测量的背屈和跖屈评估者内和评估者间ICC范围为0.84至0.99。角度测量的SEM范围为1°至3°,线性测量的SEM范围为0.3厘米至0.9厘米。方法间相关性范围为0.55至0.89。倾角计和角度计测量的背屈平均值之间没有差异。然而,倾角计跖屈值大于角度计测量值(p<0.001)。与新手评估者相比,经验丰富的评估者记录的角度计值更大(p<0.01)。背屈弓步距离测量与倾角计度数之间没有一致的线性关系。结论是,现代舞者功能性踝关节背屈最好在负重弓步姿势下使用倾角计(后位放置)进行量化。现代舞者非负重主动踝关节跖屈最好通过将倾角计放置在足背来量化。距离法不能直接与角度测量进行比较,是个体特异性的,不能用作比较不同个体、人群或年龄组之间背屈范围的规范测量方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验