Suppr超能文献

人母血和脐血中泮库溴铵及其代谢物的改良荧光定量法

Modified fluorometric quantitation of pancuronium bromide and metabolites in human maternal and umbilical serums.

作者信息

Wingard L B, Abouleish E, West D C, Goehl T J

出版信息

J Pharm Sci. 1979 Jul;68(7):914-6. doi: 10.1002/jps.2600680737.

Abstract

The procedure for pancuronium bromid ion-pair extraction into chloroform using rose bengal and subsequent fluorometric measurement was modified by changing the extraction pH and eliminating phenol, ethanol, and acetone to give easier operation and enhanced fluorescence stability. Precision, accuracy, and sensitivty were evaluated over 0.14-0.82 microgram/ml (CV = 14; relative error = 9%) and 0.05-0.17 microgram/ml (CV = 19; relative error = 21%). Following a dose of 0.1 ml/kg for cesarean section in humans, the mean maternal arterial and umbilical venous serum concentrations of pancuronium bromide and metabolites were 0.52 and 0.12 microgram/ml, respectively, at delivery (mean of 13 min after injection).

摘要

通过改变萃取pH值并去除苯酚、乙醇和丙酮,对使用孟加拉玫瑰红将泮库溴铵离子对萃取到氯仿中并随后进行荧光测量的程序进行了改进,以使操作更简便且荧光稳定性增强。在0.14 - 0.82微克/毫升(变异系数=14;相对误差=9%)和0.05 - 0.17微克/毫升(变异系数=19;相对误差=21%)范围内评估了精密度、准确度和灵敏度。在人类剖宫产术中给予0.1毫升/千克的剂量后,分娩时(注射后平均13分钟),母体动脉血和脐静脉血清中泮库溴铵及其代谢物的平均浓度分别为0.52和0.12微克/毫升。