Suppr超能文献

应用第三代双源 CT 评估 CT 肺动脉造影阻塞评分和肺灌注缺损评分在肺栓塞中的应用。

Evaluation of CT angiography obstruction score and pulmonary perfusion defect score using the third-generation dual-source CT for pulmonary embolism.

机构信息

CT Room, The First People's Hospital of Lanzhou City, Lanzhou 730050, China.

Department of Radiation Oncology, The First Hospital of Lanzhou University, Lanzhou 730030, China.

出版信息

Clin Radiol. 2023 Sep;78(9):e627-e634. doi: 10.1016/j.crad.2023.04.017. Epub 2023 Jun 2.

Abstract

AIM

To investigate the application value of computed tomography (CT) angiography (CTA) obstruction score and pulmonary perfusion defect score on the third-generation dual-source CT for pulmonary embolism and the changes of the right ventricular function.

MATERIALS AND METHODS

The clinical data of 52 patients with pulmonary embolism (PE) confirmed using the third-generation dual-source dual-energy CTPA were analysed retrospectively. These patients were divided into the severe group and non-severe group according to their clinical manifestations. The results of CTPA and dual-energy pulmonary perfusion imaging (DEPI) were recorded by two radiologists for index computation. The ratio of the maximum short-axis diameter of the right ventricle (RV) to that of the left ventricle (LV) was also recorded. The correlation analysis between RV/LV and the mean values of CTA obstruction score and perfusion defect score was performed. Correlation analysis and agreement analysis were performed on the data measured by two radiologists, CTA obstruction score, and pulmonary perfusion defect score.

RESULTS

CTA obstruction score and perfusion defect score measured by the two radiologists had good correlation and agreement. CTA obstruction score, perfusion defect score, and RV/LV were significantly lower in the non-severe group than in the severe PE group. RV/LV had a significant positive correlation with CTA obstruction score and perfusion defect score (p<0.05).

CONCLUSION

The third-generation dual-source dual-energy CT plays a positive role in assessing PE severity and RV function and can provide additional information for the clinical management and treatment of PE patients.

摘要

目的

探讨第三代双源 CT 肺动脉 CT 血管成像(CTA)阻塞评分和肺灌注缺损评分在肺动脉栓塞(PE)中的应用价值及右心室功能变化。

材料与方法

回顾性分析 52 例经第三代双源双能 CTPA 证实的肺动脉栓塞患者的临床资料。根据临床表现将患者分为重症组和非重症组。由 2 位放射科医生记录 CTPA 和双能肺灌注成像(DEPI)的结果,并计算指标。记录右心室(RV)最大短轴直径与左心室(LV)最大短轴直径的比值。分析 RV/LV 与 CTA 阻塞评分和灌注缺损评分均值的相关性。对 2 位放射科医生测量的数据、CTA 阻塞评分和肺灌注缺损评分进行相关性分析和一致性分析。

结果

2 位放射科医生测量的 CTA 阻塞评分和灌注缺损评分具有良好的相关性和一致性。非重症组的 CTA 阻塞评分、灌注缺损评分和 RV/LV 均显著低于重症组。RV/LV 与 CTA 阻塞评分和灌注缺损评分呈显著正相关(p<0.05)。

结论

第三代双源双能 CT 对评估 PE 严重程度和 RV 功能具有积极作用,可为 PE 患者的临床管理和治疗提供更多信息。